speciFicAtiOns

Measurement:
Range:

0.1 µΩ to 999.9 mΩ

(Subject to supply voltage and leads used)
Accuracy:

Voltage:

±0.5% ± 0.1 mV

Current:

±0.5% ± 0.1 A

Resistance: Better than 1% from

100 µΩ to 100 mΩ

current Lead Resistance (Megger supplied leads)
2 x 16 ft (5 m) 25 mm

2

current leads

8 mΩ

2 x 16 ft (5 m) 50 mm

2

current leads

4 mΩ

2 x 33 ft (10 m) 70 mm

2

current leads

5.4 mΩ

2 x 49 ft (15 m) 95 mm

2

current leads

6 mΩ

Maximum continuous test time
More than 10 minutes at 200 A @ 68° F (20º C) ambient.
power supply

for full output (additional smoothed):

100 to 130 V 50/60 HZ with a load

less than 11 mΩ including current leads

ORDeRing inFORMAtiOn

item (Qty)

cat no.

DLRO200-115 High Current Digital Low Resistance Ohmmeter
115 V (English QWERTY keyboard)

DLRO200-115 E

Included Accessories

16 ft. (5 m) Lead set comprising 2 x 25 mm

2

current leads with clips and 2 potential

leads with clips

6220-787

Download Manager

6111-442

User Guide on CD-ROM

6172-763

RS232 download cable

25955-025

Quick Start Guide (English)

6172-782

item (Qty)

cat no.

Optional Accessories at extra cost

16 ft. (5m) Lead set in bag comprising:

6220-755

2 x 50mm

2

current leads with clamps and

2 x potential leads with clips
49 ft. (15m) Lead set comprising 2 x 95 mm

2

current leads with clamps and

2 x potential leads with clips

6220-757

33 ft. (10m) Lead set comprising 2 x 70 mm

2

current leads with clamps and

2 x potential leads with clips

6220-756

DLRO 200-115

Digital Low Resistance Ohmmeter

UK

Archcliffe Road, Dover
ct17 9en england
t +44 (0) 1 304 502101
F +44 (0) 1 304 207342
[email protected]

UniteD stAtes

4271 Bronze Way
Dallas, tX 75237-1019 UsA
t 1 800 723 2861 (UsA only)
t +1 214 333 3201
F +1 214 331 7399
[email protected]

OtheR technicAL sALes OFFices

Valley Forge UsA, college station
UsA, sydney AUstRALiA, täby
sWeDen, Ontario cAnADA, trappes
FRAnce, Oberursel geRMAnY, Aargau
sWitZeRLAnD, Kingdom of BAhRAin,
Mumbai inDiA, Johannesburg sOUth
AFRicA, and chonburi thAiLAnD

Registered to ISO 9001:2000 Reg no. Q 09290

Registered to ISO 14001 Reg no. EMS 61597

DLRO200-115_Ds_en_V04

www.megger.com
Megger is a registered trademark

connected there until all tests have been completed. When the

voltage leads make contact across a joint, the DLRO200-115 detects

that all four leads are connected, carries out a test and stops. When

you move to the next joint the DLRO200-115 detects the already

completed circuit automatically and carries out the next test, and

so on until all joints have been tested. The results may be stored

automatically and may be recalled to the display or downloaded for

review.

test Modes:

Manual, Auto, Continuous.

test time:

10 seconds NORMAL /AUTO mode.

Refreshed every 2 seconds in CONTINUOUS

mode

Display:

Large, high resolution backlit liquid crystal

display

Warnings

Current flowing: - LED. Other warnings are

shown on the lcd display.

Data transfer

Real time or batch download via RS232

using Download Manager.

storage capacity:

300 result sets and memo, battery backed

for 10 years.

Memo field:

160 characters max.

test current
Range:

Filtered direct current; 10 A to 200 A d.c.

Accuracy:

±2% ±2 A

Voltmeter input
impedance:

>200 kΩ

hum rejection:

5 V rms 50 Hz/60 Hz

temperature
Operation:

14 to +122º F (-10 to +50º C)

storage:

-13 to 149º F (-25 to +65º C)

calibration:

68° F (20º C)

co-efficient:

<0.05% per º C

Max. humidity:

95% RH non-condensing

Maxi Altitude:

6562 ft. (2000 m)

safety:

IEC61010 – (1995)

eMc:

EN61326 annex A (heavy industrial)

Dimensions:

16.4 x 9.84 x 10.63 in.

(410 x 250 x 270 mm)

Weight:

31.97 lbs. (14.5 kg) excluding test leads