Portable ac hipot test sets, Advantages, Pft model specifications – Atec High-Voltage-PFT Series User Manual

Page 2

Advertising
background image

HIGH VOLTAGE, INC.

31 County Rt. 7A • Copake, NY 12516 • (518) 329-3275 • Fax: (518) 329-3271
E-Mail: [email protected]

Web: www.hvinc.com

High Voltage, Inc. designs and manufactures high voltage test equipment for utility and industrial applications. Also available are Very Low

Frequency (VLF) high voltage AC test sets, oil dielectric test sets, AC and DC instrumented test sets, cable fault locators and other products.

Revised 10/18/07

Input

HV Output

PFT Model Specifications

Advantages

PFT-103CM

PFT-303CM

PFT-503CM

PFT-1003CM

120 V, 60 Hz, 15A, or 230 V, 50/60 Hz, 8A

0-10 kVac, 1kVA resistive load

3 kVA capacitive load
Up to 300 mA current

0-100 kVac, 1 kVA resistive load

3 kVA capacitive load

Up to 30 mA current

0-50 kVac, 1kVA resistive load

3 kVA capacitive load

Up to 60 mA current

0-30 kVac, 1kVA resistive load

3 kVA capacitive load
Up to 100 mA current

20 ft. (6m) long shielded output cable

with alligator clamp and hook for test connections

3kVA: 1 hour ON, 1 hour OFF

1kVA: continuous

<5%

2% F.S.

3.5 inch

Scaled 0-5/10 kVac

3.5 inch

Scaled 0-50/100 kVac

3.5 inch

Scaled 0-25/50 kVac

3.5 inch

Scaled 0-12/30 kVac

3.5 inch

Scaled 0-40 mAac

3.5 inch

Scaled 0-1.0

mAac

, with x1, x10, x100 Range Multiplier

Top Toroid

(No output cable)

21È w x 11.25È d x 15.25È h

533 mm w x 286 mm d x 387 mm h

High Voltage Tank included in controls

13È w x 13È d x 22È h

330 mm w x 330 mm d x 559 mm h

62 lbs. (28kg)

75 lbs. (34kg)

75 lbs. (34kg)

Control–35 lbs. (16kg)

HV Tank–85 lbs. (39kg)

Models below 100 kVac are single piece units with a shielded cable output for fast and easy test setup. The

PFT-103CM, PFT-303CM, PFT-503CM, and PFT-1003CM are compensated enabling testing of 3 kVA loads with a

power draw of 1.5 kVA and operate from a conventional electrical source*. In addition, these units include a dual range

kilovolt meter, triple range output current meter and a guard/ground return mode enabling the operator to measure the

total current to ground or only the current flowing through the sample under test.

Portable AC Hipot Test Sets

Note: For 230 volt line input, an F is suffixed to the model number.

PFT-301CM

0-30 kVac, 1kVA resistive load

33 mA current

120V, 60 Hz, 10A

or 230V, 50/60 Hz, 5A

1kVA, 1 hour ON,

1 hour OFF

700VA: continuous

3.5 inch

Scaled 0-30 kVac

3.5 inch

Scaled 0-3.0 mAac

with x1, x10 x100 Range

Multiplier

17È w x 11.5È d x 14È h

431 mm w x 292 mm d

x 365 mm h

45 lbs. (20kg)

PFT-301CM Control Layout

PFT-503CM Control Layout

*3 kVA output power is only available with a capacitive load sized to draw 3 kVA at full rated output.

Available output current decreases with other loads.

at full output voltage in ground

mode but not guard mode

Output

Termination
Duty

Distortion
Meter Accuracy

Kilovolt Meter

Current Meter

Control

Dimensions
H.V. Tank

Dimensions
Weight

2.5 mA

1.0 mA

14 mA

20 mA

2.0 mA

No Load Current:

Advertising