Atec PMM-7010 User Manual

Page 2

Advertising
background image

Narda Safety Test Solutions Srl

Via Leonardo da Vinci, 21/23

20090 Segrate (Milano) - ITALY

Phone.: +39 02 269987-1

Fax: +39 02 269987-00

E-Mail:

[email protected]

Internet:

www.narda-sts.it

PMM 7010
SPECIFICATIONS

Frequency range

Resolution

Uncertainty

150 kHz ÷ 1 GHz

10 Hz

< 3 ppm

RF input

VSWR @ input attenuator = 10 dB

@ input attenuator = 0 dB

Attenuator

Pulse limiter

Z

in

50 Ω,

N fem.

< 1.2

< 1.2; < 1.4 above 30 MHz

0 ÷ 35 dB in 5 dB steps

0 ÷ 50 dB in 2 dB steps above 30 MHz

Internal, active for conducted measurements range (0,15 ÷ 30 MHz)

Maximum input level

(without damage)

Sinusoidal voltage

Pulsed spectral density

140 dB

µ

V (2 W)

100 dB

µ

V/MHz

IF bandwidth (RBW)

3, 10, 30, 100, 300 kHz:

-6 dB

9, 120 kHz:

compliant to CISPR 16-1-1

Noise level

(Hold time = 1 s)

0.15 ÷ 30 MHz (9 kHz RBW)

< 14 dB

u

V (QP) < 7 dB

u

V (AVG)

30 ÷ 1000 MHz (120 kHz RBW)

< 14 dB

u

V (QP) < 7 dB

u

V (AVG)

Spurious

(Peak det., Hold time = 10 ms)

< 20 dBµV

CISPR detectors

Simultaneous:
Peak, Quasi-Peak, Average, C-Average, RMS, RMS-Average

Smart Detector function

Hold time

According to CISPR 16-1-1

0.2 ms ÷ 120 s

PES – PMM Emission Suite PC software

Creation of scan tables, limits, factors

Reporting, export/import of measurements and settings

Trace comparison, marker, zoom, peaks finder

Operating modes

Sweep: automatic scanning receiver

Manual: manual tuning receiver

Analyzer: spectrum analyzer mode

Measuring units

dBm, dBµV, dBµA, dBpW, dBµV/m, dBµA/m, dBpT
Display dynamic: 80 ÷ 200 dB

Uncertainty

± 1.0 dB (150 kHz ÷ 1 GHz S/N > 20 dB)

Compliance to CISPR 16-1-1

Full compliance of Quasi-Peak detector for PRF ≥ 20 Hz

Demodulation

AM – FM with internal loudspeaker and volume control

I/O

RS-232, USB, remote control for other PMM LISN

Operating temperature

-5° ÷+ 45°C

Power supply

12 V DC, 0.8A; universal AC adapter

Internal LISN

Frequency range

Rated current

Maximum line voltage

Line frequency

CISPR-equivalent circuit

EUT socket

150 kHz ÷ 30 MHz

16A

250 V AC – 350 V DC

DC ÷ 60 Hz

50 Ω // (5 Ω + 50 uH)

SCHUKO 2P+E

Dimensions

235x105x335 mm

Weight

5.0 kg

08

/1

2 S

pe

cific

ati

on

s

su

bj

ect

to

c

ha

ng

e

s

w

ith

ou

t

pr

io

r

n

o

tice

Ordering information
7010

EMI receiver 150 kHz - 1 GHz

Includes:
- AC adapter mod. 9010/AC

- PC software PMM Emission Suite

- Calibration certificate
- USB, RS-232 cables
- User manual

OPTIONS

- 9010/RAV

CISPR RMS-AVG detector

- 9010/RMA

19” rack-mounting kit

Advertising