Specifications in brief

Frequency
Range

SME02/03

5 kHz to 1.5/3 GHz

SME03E/06

5 KHz to 2.2/6 GHz

Resolution

0.1 Hz

Setting time

after IEC/IEEE-bus delimiter

<10 ms

after trigger pulse in list mode

<500

µ

s

Phase offset

adjustable in steps of 1

°

Reference frequency

standard

option SM-B1

Aging (after 30 days of operation

1 x 10

6

/year

<1 x10

9

/day

Temperature effect (0 to 55

°

C) 2

x

10

6

<5 x10

8

Spectral purity
Spurious signals

Harmonics <

30 dBc, <

26 dBc with SM-B3/-B8/-B9

Nonharmonics at
>5 kHz from carrier, f <1.5 GHz

<

80 dBc

SSB phase noise at 20 kHz from carrier, 1 Hz bandwidth,
FM/

ϕ

M deviation <5% of max. deviation

<93.75 125

250 MHz 0.5

1

2

3

6 GHz

<

129 <

140 <

137

<

132 <

126 <

120 <

116 <

116 dBc

Residual FM, rms (f=1 GHz)
0.3 to 3 kHz (CCITT)

<1 Hz

0.03 to 20 kHz

<4 Hz

Level

144 to +13 dBm

Resolution

0.1 dB

Accuracy for levels >

127dBm

f <1.5 GHz

±

1 dB

f >1.5 GHz

±

1.5 dB

f >3 GHz

±

2 dB

Level frequency response at 0 dBm

1 dB, typ. 0.3 dB

Overload protection

protects the unit from externally
applied RF power (50

source) and

DC voltage, SME02 and 03:

50 W/

35 V; SME06:

1 W/0 V

Simultaneous modulation

any combination of AM, FM (

ϕ

M),

pulse modulation and DM (DM = FSK,
4FSK, FFSK, GFSK, GMSK or

QPSK)

Frequency modulation

with option SM-B5

Operating modes

internal, external AC/DC, two-tone
with two separate channels FM1 and
FM2

Maximum deviation

depending on carrier frequency:
500 kHz (

<

130 MHz) to 4 MHz

(6 GHz)

Setting error at AF=1 kHz

<3% of reading + 20 Hz

FM distortion at AF=1 kHz
and 50% of max. deviation

<0.5%, typ. 0.05%

Modulation frequency range

for maximum deviation

DC to 500 kHz

for <25% of max. deviation

DC to 2 MHz

Carrier frequency offset with FM

depending on carrier frequency:
<50 Hz (f

c

<

93.75 MHz) to

<100/200 Hz (f

c

1.5/3 GHz)

+1% of deviation

Phase modulation

with option SM-B5

Operating modes

internal, external AC/DC, two-tone
with two separate channels

ϕ

M1 and

ϕ

M2

Maximum deviation

depending on carrier frequency:
5 rad (f

c

<130 MHz) to 40 rad

(f

c

6 GHz)

Setting error at AF=1 kHz

<3% of reading + 0.01 rad

Distortion at AF=1 kHz and
50% of max. deviation

<1%

Modulation frequency range

DC to 100 kHz

Digital modulation

with option SME-B11,
standard in SME03E

Modulation modes

FSK, 4FSK, FFSK, GFSK, GMSK,
QPSK,

π

/4 DQPSK

Operating modes

internal, external

Internal data generator

programming of data, level switching
and burst output

Storage capacity

3

x 8192 bit

Frequency accuracy

same as reference frequency

PRBS (pseudo-random bit sequence) selectable lengths: 2

9

1, 2

15

1,

2

20

1, 2

21

1 or 2

23

1

FSK

to Cityruf, POCSAG, FLEX specs

Shift, filtered

4/4.5/4.8 kHz

unfiltered

0.01 to 400 kHz, maximum shift
depending on carrier frequency

Data rate, filtered

0.05 to 90 kbit/s

unfiltered

0.05 to 1900 kbit/s

FFSK

to Cityruf, POCSAG specifications

Shift

1.5/2/3/3.5/4/4.5 kHz

Data rate

0.05 to 90 kbit/s

4FSK

to APCO25, ERMES, FLEX,
MODACOM specifications

Shift

0.01 to 400 kHz, maximum shift
depending on carrier frequency

Data rate

1 to 24.3/27 to 48.6 kbit/s

GFSK

to CT2, CT3, DECT specifications

Shift

18/160/288 kHz as well as non-
standard shifts

Data rate

10 to 585/640 to 1170 kbit/s

GMSK

to CDPD, GSM1800, DSRR, GSM,
MC9, MD24 to MD192,
MOBITEX8000 specifications

Data rate

2.4/3.6/4/4.8/6/8/9.6/10/12/
16/19.2/270.833/1000 kbit/s

QPSK

, π

/4 DQPSK

to APCO25, MSAT, NADC, PDC,
TETRA, TFTS specifications

for f >3 GHz

not specified

Data rate

1 to 24.3/27 to 48.6 kbit/s

Filter

cos0.35/0.4/0.5/0.6

cos0.2/0.35/0.4/0.5/0.6

Amplitude modulation, pulse modulation, internal modulation generator, LF gen-
erator, multifunction generator, stereo multiplex signal, VOR modulation signal,
ILS modulation signal, pulse generator and sweep see SMT, page 198

List mode

automatic, single-shot, manual,

(not SME03E)

externally triggered

Max. number of channels

2000

Step time

1 ms to 1 s

Remote control

IEC 625 (IEEE 488)

Command set

SCPI 1992.0

General data
Power supply

90 to 132/180 to 265 V,
47 to 440 Hz, autosetting to AC volt-
age, max. 300 VA

Dimensions (W x H x D)

435 mm x 192 mm x 460 mm

Weight

25 kg for fully equipped unit

Ordering information

Signal Generator SME02

1038.6002.02

SME03

1038.6002.03

SME03E

1038.6002.13

SME06

1038.6002.06

Options
Reference Oscillator OCXO

SM-B1

1036.7599.02

LF Generator

SM-B2

1036.7947.02

Pulse Modulator for SME02

SM-B3

1036.6340.02

Pulse Modulator

for SME03

SM-B8

1036.6805.02

Pulse Modulator

for SME06

SM-B9

1039.5100.02

Pulse Generator (only in combination
with SM-B3, SM-B8 or SM-B9)

SM-B4

1036.9310.02

FM/

ϕ

M Modulator

SM-B5

1036.8489.02

Multifunction Generator

SM-B6

1036.7760.02

DM Coder

SME-B11

1036.8720.02

DM Memory Extension (8 Mbit)

SME-B12

1039.4090.02

FLEX Protocol

SME-B41

1039.5645.02

POCSAG Protocol

SME-B42

1039.5745.02

Rear Connectors
for RF and LF

SME-B19

1039.3907.02

Advertising