Field dry-wells – Atec Fluke-9141 User Manual

Page 2

Advertising
background image

diameter for doing comparison calibra-
tions. Insert C has six 1/4-inch-diameter
wells for multiple probe calibrations, and
Insert D has three pairs of metric sized
wells.

9140

The 9140 has a temperature range of
35 °C to 350 °C, and it reaches its maxi-
mum temperature in 12 minutes. At six
pounds, it’s small enough to easily carry
in one hand. It’s truly a unique innovation
in dry-wells.

The unit has a stability of ±0.05 °C or

better and a uniformity of at least 0.4 °C
in the largest-diameter wells and 0.1 °C
in the smaller wells. Despite its small
size, this unit performs.

Use the display, calibrated to ±0.5 °C, as

your reference, or use an external ther-
mometer for maximum calibration accuracy.
With three removable inserts to choose
from, the 9140 is as versatile as it is fast.

9141

Here’s an upright unit you’re going to
love. It does calibrations up to 650 °C,
weighs only eight pounds, and heats up
to 650 °C in only 12 minutes—12! This
dry-well does everything but get legs

and walk to the job for you. (And we’re
working on one that does that too.)

This four-inch-wide dry-well is amaz-

ing. You can control all functions from the
front panel or hook it up to your PC with
its built-in RS-232 port. And just like the
9140, it works with all of our software
described on page 82.

It has three removable well inserts

available, an optional carrying case, a
NIST-traceable calibration, and the best
price in the industry.

Specifications

9103

9140

9141

Range

–25 °C to 140 °C (–13 °F to 284 °F)

at 23 °C ambient

35 °C to 350 °C (95 °F to 662 °F)

50 °C to 650 °C (122 °F to 1202 °F)

Accuracy

±0.25 °C

±0.5 °C (holes greater than 1/4"

[6.35 mm]: ±1 °C)

±0.5 °C to 400 °C; ±1.0 °C to 650 °C

(holes greater than 1/4": ±2 °C)

Stability

±0.02 °C at –25 °C
±0.04 °C at 140 °C

±0.03 °C at 50 °C

±0.05 °C at 350 °C

±0.05 °C at 100 °C
±0.12 °C at 500 °C
±0.12 °C at 650 °C

Well-to-Well
Uniformity

±0.1 °C between similarly sized wells

±0.1 °C with similarly sized wells

±0.1 °C below 400 °C, ±0.5 °C above

400 °C with similarly sized wells

Heating Times

18 minutes from ambient to 140 °C

12 minutes from ambient to 350 °C

12 minutes from ambient to 650 °C

Cooling Times

20 minutes from ambient to –25 °C

15 minutes from 350 °C to 100 °C

25 minutes from 650 °C to 100 °C

Stabilization Time

7 minutes

Immersion Depth

124 mm (4.875")

Inserts

Insert A, B, C, or D included (specify when ordering)

Outside Insert
Dimensions

31.8 mm dia. x 124 mm (1.25 x 4.88 in)

28.5 mm dia. x 124 mm (1.12 x 4.88 in)

Computer Interface

RS-232 included with free Interface-it software (Model 9930)

Power

115 VAC (±10 %), 1.3 A or 230 VAC

(±10 %), 0.7 A, switchable, 50/60 Hz,

150 W

115 VAC (±10 %), 4.4 A or 230 VAC

(±10 %), 2.2 A, switchable, 50/60 Hz,

500 W

115 VAC (±10 %), 8.8 A or 230 VAC

(±10 %), 4.4 A, switchable, 50/60 Hz,

1000 W

Size (WxHxD)

143 x 261 x 245 mm

(5.63 x 10.25 x 9.63 in)

152 x 86 x 197 mm

(6 x 3.375 x 7.75 in)

109 x 236 x 185 mm

(4.3 x 9.3 x 7.3 in)

Weight

5.7 kg (12 lb.)

2.7 kg (6 lb.)

3.6 kg (8 lb.)

NIST-Traceable
Certificate

Data at –25 °C, 0 °C, 25 °C, 50 °C, 75 °C,

100 °C, and 140 °

Data at 50 °C, 100 °C, 150 °C, 200 °C,

250 °C, 300 °C, and 350 °C

Data at 100 °C, 200 °C, 300 °C, 400 °C,

500 °C, and 600 °C

Field Dry-Wells

Ordering Information

9103-X Dry-Well (specify X, X = A, B, C, or D

included insert)

3103-1 Insert,

blank

3103-2 Insert A

3103-3 Insert B

3103-4 Insert C

3103-6 Insert D

9316

Rugged Carrying Case

9140-X Dry-Well (specify X, X = A, B, C, or D

included insert)

3140-1 Insert,

blank

3140-2 Insert A

3140-3 Insert B

3140-4 Insert C

3140-6 Insert D

9308

Rugged Carrying Case

9141-X Dry-Well (specify X, X = A, B, C, or D

included insert)

3141-1 Insert,

blank

3141-2 Insert A

3141-3 Insert B

3141-4 Insert C

3141-6 Insert D

9309

Rugged Carrying Case

Advertising