Featur es – Atec TTC-T-Berd-211 User Manual

Page 3

Advertising
background image

Featur

es

I

nformation technicians need to ensure optimum T1 performance is readily obtained, quantified, and qualified by
the T-BERD 209A/211’s comprehensive testing and reporting options.

Jitter Alarm and Trigger
(T-BERD 211 only)

• Front panel indicator provides fast identifica-

tion of jitter problems; jitter measurements
across the full 10 Hz to 40 kHz range facilitate
isolation of multiplexer and channel bank clock
recovery problems

Pulse Shape Measurement
and Analysis

• Determine if the output of a network element

is acceptable

• Evaluate customer premises and network equip-

ment adherence to pulse mask specifications at
the point of sampling

• Use DSX and network interface masks to mea-

sure pulse shape and width, rise time, fall time,
undershoot, and overshoot

Received Signal Level
Measurements

• Analyze signal strength to diagnose transmission

problems caused by high/low signal levels

G.821 Measurements

• Perform error analysis per G.821 specification

standards to verify circuit quality. Capture data
including unavailable seconds, percent avail-
ability, degraded minutes, percent degraded
minutes, severely errored seconds, percent
severely errored seconds

Stress Pattern Testing

Generate a full suite of patterns to rapidly locate

and isolate line problems. Patterns include:

• Automated Multipattern Tests

Detect elusive bridge taps using automated
BRIDGTAP sequence and perform qualifica-
tion tests with the user-configurable MULTI-
PAT

sequence

• Long User Pattern

Stress repeater ALBO circuits with 55 OCTET,
T1 DALY, and other long user test patterns

• All Zero Stress Pattern

Identify circuits not configured for or incom-
patible with B8ZS data

Intelligent Repeater Loopcodes

• Loop up and loop down individual addressable

office repeaters and line repeaters, or transmit
maintenance switch commands

ESF Testing

• Emulate and loop back network devices that

accept either in-band or ESF out-of-band (data
link) loopback codes

• Decode ESF PRMs to confirm data link opera-

tion and network performance; emulate ANSI
T1.403 compatible CSU equipment during cir-
cuit installation and qualification

Advertising