Atec T-R-100ADM Mk4 User Manual

Page 2

Advertising
background image

Note: Due to the company’s continuous research programme, the information above may change at any time without prior notification. Please check that you have the most recent data on the product.

T&R Test Equipment Ltd, 15-16 Woodbridge Meadows, Guildford, Surrey, GU1 1BJ, UK

Tel: +44 (0)1483 207428 Fax: +44 (0)1483 511229 email: [email protected]

www.trtest.com

Main Output

The main output on the unit has four taps, allowing the selection of
output voltages up to 240V and output currents up to 100A.

*Off time of 15 minutes. On times based on an ambient temperature of 25°C.
**6 second intermittent ratings available with 230V supply.

I Limit Mode

The main output has a current limit mode that gives very fine control
of output currents up to 10A. It also allows fine current control into
very low impedance loads such as digital relays.

Auxiliary AC and DC Outputs

A switched, isolated auxiliary DC supply with current limit protection
is available to power the relay under test, and a 110Vac auxiliary
output is available for tests.

DC stabilised output

24V, 48V, 60V

1.0A

110V, 220V

0.23A

Fixed AC output

110Vac

300mA

Metering

The output is metered by a digital true RMS system with a single
cycle capture memory ammeter—whenever the timer stops and the
output is switched off, the reading is held on the display. A current
trip is set to 110% of full scale of the selected metering range.

Supply Requirements

115/230V±10% auto-selecting 50/60Hz 1ph 1200VA max

Accessories

Operating manual, output lead set, mains lead, spare fuses and
carry strap.

Timing System

Range

0-999.999s/9999.99s/99999.9s autoranging

Resolution

1/10/100ms

Accuracy

0.01%rdg+2d (+4d current operated mode)

Contact o/c 24V
Contact s/c

20mA

Vdc

24—240V

Each contact circuit will auto-select for normally open or normally
closed contacts. A DC voltage of 24—240VDC may also be used to
trigger either timer channel. Contact state is shown by an LED. The
output automatically switches off at the end of the test to safeguard
the relay under test.

Pulse mode is used for setting the current level in devices sensitive
to heating. Current is injected for 200ms.

RS232 and T&R Link

An RS232 port is provided to allow connection to a PC or a printer.
The T&R Link output allows a T&R DVS3 mk2 voltage source to
phase lock to the 100ADM mk4 current..

Protection and Safety

The unit is designed to comply with BSEN61010 and is CE marked.
An earth terminal is provided for connection to a local earth for
testing in sub-station environments.

Dimensions

Weight

380mm x 314mm x 221mm

20.0kg

Including handle and corner protectors

Temperature Range

Storage

-20°C to 60°C

Operating

0°C to 45°C

Lead Set specifications

The 100ADM mk4 is supplied with a lead set consisting of:
2 x 5m 25mm

2

100A leads terminated in M10 ring crimps

2 x 5m, 2 x 0.5m 2.5mm

2

25A leads terminated in 4mm plugs

1 x 5m 2 core 0.75mm

2

lead terminated in 4mm plugs

The lead set is supplied in a plastic carrying case.
Lead set weight 5.3kg including case.

Optional Accessories

Filter unit, RB10 resistor box, Printer, pushbutton lead for runback
timing on disc induction relays.

The standard 100ADM mk4 is
supplied in an aluminium case. It is
also optionally available mounted
in a Pelicase with space for leads.

100ADM mk4 Specification

100ADM mk4 Data Sheet Rev 1 03/10/12

8

Range

Current

Output

@230V

Cont

5 min

*

1 min

*

O/C

Load V

10V

33A

67A

100A

10.5V

8.7V

@

100A

35V

10A

20A

30A

36V

32V

@30A

100V

3A

6A

10A

108V

99V

@10A

240V

1A

2A

3A

276V

259V

@3A

240Vdc

1A

2A

3A

Range

Current (A)

Output V

@230V

Short

circuit

Cont.

5 min

2 min

O/C

Load V

10V

10A

3A

6A

10A

8.6V

5V

@5A

35V

3A

1A

2A

3A

29V

13V

@2A

100V

1A

0.3A

0.6A

1A

88V

40V

@0.6A

240V

0.3A

0.1A

0.2A

0.3A

224V 130V

@0.2A

Range

Resolution

Trip

current

Accuracy

Acquisition

time

2.000A

0.001A

2.2A

±0.5%rdg±5d

20ms

10.00A

0.01A

11A

±0.5%rdg±5d

20ms

20.00A

0.01A

22A

±0.5%rdg±5d

20ms

100.0A

0.1A

110A

±0.5%rdg±5d

20ms

Mode

Timer Start

Timer Stop

Internal start

Press ‘ON’

C1 or C2 change

1 contact

C1 1st change

C1 1 2nd change

2 contacts

C1 change

C2 change

Current operated

Current > 10% of

Current < 10% of

Pulse

Press ‘ON’

200ms

Advertising