100 mhz band differential probe, Specifications – Atec Yokogawa-700924 User Manual

Page 2

Advertising
background image

100 MHz band differential probe

Subject to change without notice.

[Ed : 01/b] Copyright ©1999

Printed in Japan, 907(YG)

YOKOGAWA ELECTRIC CORPORATION
Measurement Sales Dept./Phone: 81-422-52-6614, Fax: 81-422-52-6624
Recorders · DAC Sales Dept./Phone : 81-422-52-6765, Fax : 81-422-52-6793

YOKOGAWA CORPORATION OF AMERICA

Phone: 770-253-7000, Fax: 770-251-2088

YOKOGAWA EUROPE B.V.

Phone: 31-33-4-641611, Fax: 31-33-4-631202

YOKOGAWA ENGINEERING ASIA PTE. LTD Phone: 65-783-9537, Fax: 65-786-6650

MS-06E

700924

Example of probe connection with DL1540CL digital oscilloscope

Two or more differential probes can be connected to measure signals with different ground
levels on each channel.

●

Overrange (outside-range) indicator

This light turns on when the permitted
differential voltage is exceeded. During
DC measurements, it turns on as an
alert at voltages of 350 V and higher
with a 1/100 range setting, and at
voltages of 1400 V and higher with a
1/1000 range setting.

●

Power switch

●

AC/DC adapter connector

(on side of probe)

This DC adapter powers the probe. The
probe can also be powered by four dry
cells without using an AC/DC adapter.

●

1/100-1/1000 selector switch

This switch is used to select the input
voltage attenuation ratio.

■

Specifications

Input type:

Balanced differential input

Frequency band:

DC up to 100 MHz (-3 dB)

Input attenuation ratio:

Switched between 1/100 and 1/1000

Input impedance:

Approximately 4 M

Ω

, approximately 10

pF parallel

Gain accuracy:

±

2% (common mode voltage

Ϲ

400 V)

±

3% (common mode voltage

Ϲ

1000 V)

Maximum allowed differential voltage:

±

350 V (DC + ACpeak) or 250 Vrms (1/

100 range)

±

1400 V (DC + ACpeak) or 1000 Vrms

(1/1000 range)

Maximum common mode input voltage:

±

1400 V (DC + ACpeak) or 1000 Vrms

(both 1/100 and 1/1000 ranges)

Maximum input voltage:

±

1400 V (DC + ACpeak) or 1000 Vrms

(1/1000 range)

Common Mode Rejection Ratio (CMRR):

-80 dB (60 Hz), -50 dB (1 MHz)

Output voltage:

±

3.5 V

Output impedance:

Used with 1 M

Ω

input impedance

Power supplies:

Dry cells, four R6P (SUM-3); when using
the AC/DC adapter, use an output voltage
of 6 V/200 mA or greater/center plus

Dry cell life:

Approximately 2 hours under continuous
use

External dimensions (approximate):

207 mm

✕

83 mm

✕

38 mm*

1

Total length:

Approximately 1.5 meters

Weight:

Approximately 800 grams (excluding dry
cells)

Approved standards:
EMC:

EN55011: 1991 + A1: 1997 + A2: 1996
EN50082-1: 1992

Safety:

EN61010-1: 1993 + A2: 1995
EN61010-2-031: 1994

*1: 38 mm is listed as the maximum value.

Note: Dry cells and AC/DC adapter not included.

Model name

Code

Description

Differential probe

700924

DC to 100 MHz band

■

Model and Codes

Each 700924 differential probe comes standard with red and black pincher tips (one each).

Item

Part No.

Order Q'ty

Red pincher chips

B9852MC

3

Black pincher chips

B9852MB

3

■

Spares

Use this product in combination with 701856 (high-speed module) when using it with
DL708E or DL716. See the DL Series accessory catalog for information on selecting a
conversion adapter and other components. Bulletin 7009-63E