WAVEFORM PROCESSING

Deskew – Channel to channel deskew ±10 ns
may be manually entered for better timing mea-
surements and more accurate math waveforms.
Arithmetic Operators – Add, Subtract,
Multiply, Divide.
Autoset – Single-button, automatic setup on
selected input signal for vertical, horizontal, and
trigger systems.

DISPLAY CHARACTERISTICS

Graticules – Full, grid, cross-hair, frame, NTSC,
PAL, SECAM, vectorscope 100% and 75% color
bars (with optional TDS 3VID and TDS 3SDI video
application modules).
Format – YT, XY and Gated XYZ (XY with Z-axis
blanking available on TDS 30X4 only).

I/O INTERFACE

Hardcopy Port (standard) – Centronics-type
parallel.
TDS 3GM Communications Module –
GPIB (IEEE –488.2) Programmability: Full talk/lis-
ten modes; Control of all modes, settings, and
measurements.
RS-232-C Interface Programmability: Full talk/lis-
ten modes; Control of all modes, settings, and
measurements. Baud Rate up to 38,400. DB-9
male connector.
Programmer Manual: (071-0381-00).

TDS 3VM Communications Module –
VGA: Monitor output for direct display on large
VGA-equipped monitors. DB-15 female connector,
31.6 kHz sync rate, EIA RS-343A compliant.
RS-232-C Interface Programmability: same as
TDS 3GM.
Programmer Manual: same as TDS 3GM.
TDS 3EM Communications Module –
Ethernet Port: 10Base-T with RJ-45 connector.
Provides local area network printing and pro-
gramming interface.
RS-232-C Interface programmability: same as
TDS 3GM.
Programmer Manual: same as TDS 3GM.
Note: Only one Communication Module may be
installed at a time.
All Communication Modules include WaveStar

Software for oscilloscopes 30-day, full-functioning
product demo.

HARD COPY CAPABILITY

Graphics File Formats – Interleaf (.img), TIF,
PCX (PC Paintbrush), BMP (Microsoft Windows),
and Encapsulated Postscript (EPS).
Printer Formats – Bubblejet, DPU-3445,
Thinkjet, Deskjet, Laserjet, Epson (9 and 24-pin).

ENVIRONMENTAL AND SAFETY

Temperature – +5 to +50°C (operating), –20 to
+60°C (nonoperating).
Humidity – 20% to 80% RH below 32°C, derate to
30% RH at 45°C (operating), 5% to 90% RH below
41°C, derate to 30% RH at 60°C (nonoperating).
Altitude – to 3,000 m (operating), 15,000 m
(nonoperating).
Electromagnetic Compatibility – Meets or
exceeds EN55011 Class A Radiated and
Conducted Emissions; EN50082-1; FCC 47 CFR,
Part 15, Subpart B, Class A; Australian EMC
Framework; Russian GOST EMC regulations.
Safety – UL3111-1, CSA1010.1, EN61010-1,
IEC61010-1.

P h y s i c a l C h a r a c t e r i s t i c s

Instrument
Dimensions

mm

in.

Width

375.0

14.8

Height

176.0

6.9

Depth

149.0

5.9

Weight

kg

lb.

Instrument only

3.2

7.0

w/battery

5.2

11.5

Characteristics (Continued)

TDS 3012, TDS 3014, TDS 3032, TDS 3034,
TDS 3052, TDS 3054

STANDARD ACCESSORIES
Probes: 2 each P3010 10X passive probes (TDS 3012), 4
each P3010 10X passive probes (TDS 3014), 2 each
P6139A 10X passive probes (TDS 3032, TDS 3052), 4
each P6139A 10X passive probes (TDS 3034, TDS 3054).
Documentation: Quick Reference Manual, User Manual,
On-line Tour Disk, Front panel overlay for non-English
languages.
Application Modules (TDS 3014, TDS 3034, TDS 3054
only): TDS 3FFT, TDS 3TRG.
Power Cord.
Accessory Tray.
Protective Front Cover: has holder for reference manual
and/or 3.5 in. floppy disks.
NIST-Traceable Certificate of Calibration.

WARRANTY INFORMATION
Three year warranty covering all labor and parts,
excluding probes.

INTERNATIONAL POWER PLUGS
Standard –
US (161-0104-00).
Opt. A1 – Universal Euro 220 V, 50 Hz (161-0104-06).
Opt. A2 – United Kingdom 240 V, 50 Hz (161-0104-07).
Opt. A3 – Australia 240 V, 50 Hz (161-0104-05).
Opt. A5 – Switzerland 220 V, 50 Hz (161-0167-00).
Opt. A6 – Japan 3 to 2 wire adapter (013-0310-00).

INTERNATIONAL USER MANUALS (TDS 3000
SERIES, TDS 3FFT, TDS 3TRG, TDS 3VID,
TDS 3TMT)
Standard –
English.
Opt. L1 – French.
Opt. L2 – Italian.
Opt. L3 – German.
Opt. L4 – Spanish.
Opt. L5 – Japanese.
Opt. L6 – Portuguese.
Opt. L7 – Simplified Chinese.
Opt. L8 – Traditional Chinese.
Opt. L9 – Korean.
Opt. LR – Russian. (TDS 3000 products only)

INSTRUMENT ACCESSORIES
TDS 3SDI –
601 Digital Video Module.
Converts ITU-R BT.601 format serial digital video to ana-
log video. Automatically detects and displays 525/60
and 625/50 formats. Provides composite and compo-
nent (RGB, YPbPr, or YC) outputs. Provides auto equal-
ization for cable lengths up to 250 m and EDH and
counting for incoming SDI signal. Adds video picture
mode with on-screen line select and vectorscope mode
with 100% and 75% color bars. Adds triggering and
vectorscope graticules for analog HDTV. Includes full
functionality of TDS 3VID Extended Video Applications
module. Includes special output cable and four 75

terminators. Ships with Quick Reference and User
Manuals in 10 languages. (Russian not available.)

Ordering Information

TDS 3BAT – Battery Pack being installed.

Application Module being installed.