2715
Characteristics
Coninued

page 7

Sweep Times – 1 µsec/div to 2 sec/div in a
1-2-5 sequence.
Sweep Accuracy – ±10% over the center 8
divisions.
Trigger – Free run, internal, external, line,
TV line, and TV field.
Trigger Amplitude –
Internal: One division or more of signal.
External: 100 mV peak minimum; DC cou-
pled (15 Hz to 1 MHz).

OTHER INPUTS/OUTPUTS

External Trigger – BNC connector, 10 k

impedance, DC coupled, 0.1 µsec minimum
pulse width; 50 V (DC + pk AC) maximum.
External Video Input – 100

impedance

DC coupled; 0-50 kHz BW; 0-1.6 V
(200 mV/div typical) signal input for vertical
deflection of CRT beam.
Video Output – 0-1.6 V of video signal,
inversely proportional to vertical display
amplitude; 0 V is top of screen; 1 k

impedance.
Sweep Gate Out – TTL level that is HI while
CRT beam sweeps.
Sweep Output – +1.3 to –1.3 V, negative-
going ramp, proportional to the horizontal
sweep; output impedance <50

.

Digital Communications – Either RS-232 or
GPIB interface provided as a no-cost option.

ENVIRONMENTAL

Temperature –
Operating: 0° to +50°C (MIL T-28800E).
Nonoperating: –55° to +75°C.
Humidity – Nonoperating: Five cycles
(120 hrs) in accordance with MIL-Std-
28800E, Class 5.
Vibration – Meets MIL T-28800E, Method
514, Procedure X (modified).
Shock – Operating and nonoperating: Three
guillotine-type shocks of 30 g, one-half
sine, 11 ms duration each direction along
each major axis; total of 18 shocks.
Altitude –
Operating: 15,000 ft.
Nonoperating: 50,000 ft.
Electromagnetic Compatibility –
EC92 EMC Directive 89/336/EEC:
Emissions:

EN50081-1.
Radiated emissions, 30 MHz to 1 GHz:
EN55022 Class B (CISPR 22 B).
Conducted emissions, 150 kHz to
30 MHz: EN55022 Class B (CISPR 22 B).
Conducted emissions, power line har-
monics, 0 to 2 kHz: IEC 555-213.

Immunity:

EN50082-1.Electrostatic discharge, 8 kV,
IEC 801-2.
Radiated immunity, 27 MHz to 500 MHz,
IEC 801-3.
No response above –90 dBm in a
3 V/meter field.
Fast transients, capacitive clamp, 1 kV
power leads, 500 V control leads, IEC
801-4.

Power line surge, 1 kV differential mode,
2 kV common mode, IEC 801-5.

GENERAL CHARACTERISTICS

Power Requirements – 105 W maximum
(1.4 A) at 115 V, 60 Hz; operates 48 Hz to
440 Hz, 90 to 132 VAC, or 48 Hz to 63 Hz,
90 VAC to 250 VAC; battery power option
available.

Dimensions (H,W,D) with Feet, Handle, and
Front-Panel Cover

mm

in.

137 x 361 x 445

5.4 x 14.2 x 17.5

Weight

kg

lbs.

<10.6

23.5

OTHER CAPABILITIES

Markers – Single marker/delta marker; next
right, next left peaks; next lower, next
higher peaks; (highest) peak find; marker to
center frequency; select start/stop frequen-
cies; transpose

markers.

Measurement Modes – Noise, carrier-to-
noise, bandwidth (user-definable "dB down"
points), 99% occupied bandwidth, signal
search, and cable TV measurements (see
Cable TV).
Time Delay Setup – Uses built-in
time-of-day clock to initiate measurement
sequences and sequence repeat interval;
START TIME, REPEAT INTERVAL, RUN N
TIMES.
PC-Based Software Package – Provides
report generation, test data analysis, data
history, channel tuning table definition,
user-defined program definition, limits
checking, alarming and 271X display
transfer.
Nonvolatile Memory –
Lithium battery backup, 124 K available;
used to save cable TV measurement results,
setup table parameters, large user-definable
key routines, antenna tables, and channel
tuning tables.
Saved Displays: 108 maximum.
Saved Front-Panel Setups: 36 maximum.
Digital Storage Display – Selectable acqui-
sition modes of positive peak only, positive/
negative peak; SAVE A, B, C, and active D
trace; up to four traces on screen; MAX
HOLD A, B; MIN HOLD C; B, C minus A;
TITLE MODE; digital storage off provides
analog display.
Ensemble Averaging – Provides weighted
averaging of display, results in reduction of
measured noise values and impulse signals.
Internal Preamp – Preamp can be switched
in/out of circuit (degrades flatness above
600 MHz, provides a maximum of 12 dB
sensitivity improvement).
Alternate Reference Level Units – dBm,
dBmV, dBV, dBµV, dBµW, dBµV/m (dBmV
and dBµV only in CATV measurement
mode).
dBµV/m Mode – Automatically compen-
sated field strength measurement with up to
five user-selected antennas.
User-Definable Power-On Status – Instru-
ment powers up to user-definable state or
supplied default settings.
Center Measure – Signal nearest center fre-
quency is centered with frequency and peak
amplitude automatically read out (not a
marker mode); the centered signal is
counted.
Signal Track – Drifting signal is kept at dis-
play center with correct frequency and peak
amplitude displayed.
Direct Plot/Print – Supports Epson FX and
LQ Series compatible Printers using RS-232
interface, or HPGL compatible plotters via
GPIB interface.

Advertising