General specifications, Operating instructions – atwood Air Conditioners (non-ducted AC-1351, AC-1501) User Manual

Page 11

Advertising
background image

AC IOM 3/01/2013 rev 1

11

Air

– Conditioner

Height - 12.8 inch (325mm)
Width

– 26.6 inch (675mm)

Length - 38.4 inch ( 975mm)
Weight

– 99 lb (45kg)

Air Discharge Plenum
Height - 2.6 inch (65mm)
Width - 21.0 inch (535mm)
Length - 21.8 inch (555mm)
Weight

– 1.1 lb ( 2.4kg)

GENERAL SPECIFICATIONS

AC Description

Model Number

13.5K Non-Ducted AC

– White

AC-1351W

13.5K Non-Ducted AC

– Black

AC-1351B

15K Non-Ducted AC

– White

AC-1501W

15K Non-Ducted AC

– Black

AC-1501B

Model 13500

Model 15000

Electrical Rating:

115V, 60Hz

115V, 60Hz

Electrical Rating:

13,500 BTU/Hr

15,000 BTU/Hr

Nominal Heating Capacity:

n/a

15,000 BTU/Hr

F.L.A. Cooling:

12.5 A

13.0 A

F.L.A. Heating:

n/a

13.0 A

Locked Rotor Amps:

63 A

63 A

Refrigerant:

R410A

R410A

Refrigerant:

18 Oz (510 g)

24 Oz (670 g)

Total Installed Weight:

84 lb (38 kg)

86 lb (39 kg)

OPERATING INSTRUCTIONS

- Turn the unit on by pressing the ON/OFF button once.
- Press the MODE button to cycle through the five mode

selections: COOL, FAN, HEAT, DRY, AUTO Cool/Heat modes.

-

- MODE

– COOL

- Cycle mode pushbutton to highlight COOL.
- You may select HIGH, MED, LOW, or AUTO fan speeds by pressing

the fan pushbutton. It is recommended that you choose Auto.

- Now select the desired room temperature (herein referred to as

SETPOINT) by pressing the TEMP up or down pushbuttons.
The readout will flash the setpoint temperature. Keep pressing
the pushbutton until it flashes your desired set point. In approx.
5 seconds the display will resume reading the actual room
temperature. The compressor will have a delayed start usually
3 minutes before unit starts to cool.
Note: Any interruption to the power supply will cause the unit to
delay compressor start up
- MODE

– FAN

- For simply re-circulating air, choose the FAN mode. Choose any of the three fan speeds by pressing FAN
button. Note: Temperature pushbuttons are invalid in FAN mode.
- MODE - HEAT
- To heat, press MODE pushbutton to highlight HEAT.
- Select desired set point temperature by pressing TEMP up or down pushbuttons. It is recommended that the
AUTO fan speed be selected.
- After the delay, the compressor will start. Usually the fan will stop and will not re-energize until the heat
exchanger has warmed and then the fan will start to blow warm air.

Thermostat control module. A “cool only”
model (AC-1351) will not have the furnace
pushbutton on the display.

Advertising