B&K Precision 2870 - Datasheet User Manual

Model 2870, Model 2860a, Specifications

Advertising
background image

For your nearest distributor, call 800-462-9832 or www.bkprecision.com

33

2870

2860A

■

Heavy Duty 1500 VDC rating

■

Ruggedized construction

■

Includes rubber boot

■

Withstands 5-foot drop

■

Extra large, high contrast LCD display

■

Gasket sealed against dirt and contaminants

■

Water resistant

■

High energy fused on all current ranges

■

Auto power off saves batteries

■

Built in probe holders

■

Non-slip grip

■

Extensive overload protection

Model 2870

■

0.25% DCV accuracy

■

True RMS

■

Autoranging

■

Analog bargraph

■

3 3/4 digit, 3200 count

■

Data hold, delay hold

Model 2860A

■

0.5% DCV accuracy

■

Manual ranging

■

3 1/2 digit, 2000 count

■

Large 0.8" LCD display

Five Year Warranty

DC Volts

Auto/Manual ranging

Manual ranging

Ranges

320mV, 3.2V, 32V, 320V, 1500V

200mV, 2V, 20V, 200V, 1500V

Resolution

100µV, 1mV, 10mV, 100mV, 1V

100µV, 1mV, 10mV, 100mV, 1V

Accuracy

±(0.25% rdg + 2 dgt)

±(0.5% rdg + 1 dgt)

Overload protection

1500V peak

1500V peak

Input Impedance

10M

Ω

10M

Ω

AC Volts

Auto/Manual ranging

Manual ranging

True RMS

avg. responding, rms reading

Ranges

3.2V, 32V, 320V, 750V

200mV, 2V, 20V, 200V, 1000V

Resolution

1mV, 10mV, 100mV, 1V

100µV, 1mV, 10mV, 100mV, 1V

Accuracy

±(1.3% rdg + 3 dgt)

±(1.25% rdg + 4 dgt)

Frequency Response

40Hz - 1kHz

40Hz - 500Hz

Overload Protection

1100V peak

1500V peak

Input Impedance

10M

Ω

10M

Ω

Current

Auto/Manual ranging

Manual ranging

AC True RMS

AC avg. responding, rms reading

Ranges

320µA, 3.2mA, 32mA, 300mA, 20A*

200µA, 2mA, 20mA, 200mA, 20A*

Resolution

0.1µA, 1µA, 10µA, 100µA, 10mA

0.1µA, 1µA, 10µA, 100µA, 10mA

Accuracy (DC)

±(1.0% rdg + 2 dgt),

±(1.0% rdg + 1 dgt),

±(2.0% rdg + 3 dgt) for 20A

±(2.0% rdg + 3 dgt) for 20A

Accuracy (AC)

±(2.5% rdg + 3 dgt)

±(1.5% rdg + 3 dgt),

±(2.5% rdg + 5dgt) for 20A

±(2.5% rdg + 4 dgt) for 20A

Frequency Response

40Hz - 1kHz

40Hz-500Hz

Overload Protection

High energy 600V, 1A full for µA/mA, High energy 600V, 15A for 20A

Resistance

Auto/Manual ranging

Manual ranging

Ranges

320

Ω

, 3.2k

Ω

, 32k

Ω

, 320k

Ω

, 200

Ω

, 2k

Ω

, 20k

Ω

, 200k

Ω

,

3.2M

Ω

, 32M

Ω

2M

Ω

, 20M

Ω

Resolution

0.1

Ω

, 1

Ω

, 10

Ω

, 100

Ω

, 1k

Ω

, 10k

Ω

0.1

Ω

, 1

Ω

, 10

Ω

, 100

Ω

, 1k

Ω

, 10k

Ω

Accuracy

±(0.5% rdg + 2 dgt)

±(0.75% rdg + 1 dgt)

±(2.0% rdg + 5 dgt) for 32M

Ω

±(1.5% rdg + 5 dgt) for 20M

Ω

Overload Protection

600V peak

600V peak

Diode Check

Tested at 1.5mA, 3.3V max typical tested at 1mA 3.2V max typical

Continuity

Beeper sounds below 200

Ω

approx.

Beeper sounds below 100

Ω

approx.

Display

0.53" LCD, 3200 count with

0.8" LCD, 1999 count

65-segment analog bargraph

Sampling rate

2/sec., 12/sec. for bargraph

2.5 /sec.

Operating Temperature

32° to 122°F (0°C to 50°C), <80% RH

Power

Single 9V battery

Battery life

200 hrs typ (alkaline)

250 hrs typ (alkaline)

Auto power off

Approx. 10 min.

Approx. 30 min.

DImensions (H x W x D)

6.88 x 3.19 x 1.25" (175 x 81 x 32mm)

6.88 x 3.5 x 1.5" (175 x 89 x 38mm)

Weight

18.3 oz. (519g)

12 oz. (353g)

Specifications

models

2870

2860A

SUPPLIED: Battery, test leads, rubber holster, manual
OPTIONAL: TL-1 Replacement Test Leads , TL-2A Deluxe Test Leads, TL-3 Accessory TIp Kit

(for TL-2A), TL-130A General Purpose DMM Kit, PR-28A High Voltage Probe,
CP-3 AC/DC Current Clamp Adapter

Carrying Case (not included): LC-29B

The “Survivor” name says it all!

*10 A continuous, 20A for 30 seconds max.

Accessories

Advertising