3. Insert 2 securing elements and screw tight.

4. Push lue duct upwards until it clicks into

position.

5. Insert metal-mesh grease ilter.

Installation

Locking screws and locking caps

1. Mark the holes for the safety screws.

Detach the extractor hood, drill holes for
the safety screws and press in wall plugs
lush with the wall.

2. Attach the extractor hood and screw in

the safety screws tightly.

3. Press the safety caps with the arrow

upwards onto the brackets until they click
into position

.

RISK OF INJURY

Check that all locking screws and locking
caps have been attached securely!
4. Connect the pipes

(see ”Connecting pipes”).

5. Connect to the power supply

(see ”Electrical connection”).

Removing the safety caps

Remove the locking caps from the brackets

using a suitable tool, e.g. a lat-blade
screwdriver.

Circulating air module

1. Place the circulating air module on the air

connection and screw tight.

2. Insert the activated-carbon ilters.

Installing the lue ducts

RISK OF INJURY

The insides of the lue ducts may have sharp
edges. We recommend wearing protective
gloves during installation.
1. Remove the protective ilm from both

lue ducts.

2. Insert lue into the guide rails and slide

down.