Reliability test, Relative humidity 90%-95%rh duration, Duration 48hrs – BeStar BMS2415-11C-08H05RW025 LF User Manual

Page 4

Advertising
background image

H

H

sensitivity difference at 1kHz shall be within

±3dB from initial value after test.

Date:

Checked by:

Approved by:

Drawn by:

4

Rev.

6

A

Note

Drawn

Date

5

B

www.be-star.com [email protected]

3

Page:3 of 5

2

1

Speaker

A

B

4.6 Drop Test
Height 100cm (in state of packing)
Times 10 (Drop onto hardwood board)

4.5 Temperature Cycle Test
Cycle 4

4.3 Low Temperature Test
Temperature -20±3

Duration 48hrs

4.1 Load Test
Power 0.5W
Duration 96hrs

4.4 Damp Heat
Temperature 40±3

Relative Humidity

90%-95%RH

Duration

96hrs

All these tests above should be measured after leaving normal temperature for 1hrs.

4.2 High Temperature Test
Temperature

+70

±2

Duration

48hrs

-20

1hrs

T

h

is

p

ri

n

t

and

i

n

fo

rm

a

ti

on

t

he

re

i

n

a

re

p

rop

ri

e

ta

ry

t

o

B

e

s

ta

r E

le

c

tr

on

ics

I

ndu

s

tr

y

C

o

.,

L

td.

and

s

ha

ll

no

t

be

u

s

ed

i

n

w

ho

le

o

r

in

p

a

rt

w

it

hou

t

it

s

wr

itt

en

c

on

tent

D

C

E

25

1hrs

1hrs

+70

F

4. Reliability Test

G

D

C

25

E

F

G

4

BMS2415-11C-08H05RW025 LF

6

5

3

2

1

朱成兴

A

06/11/04

BMS2415-11C-08H05RW025 LF

程久生

DRG NO: BS/TES01.679A

朱成兴

高 正

06/11/04

Advertising