DRG NO: BS/TES01.990A

SMS2020-08H4.5 LF

4.3 Low Temperature Test
Temperature -40±3°C
Duration 120hrs

4.1 Load Test
Power (Nom) 0.5W(sine wave)
Duration 120hrs

4.2 High Temperature Test
Temperature

+105

±3°C

Duration

120hrs

4. Reliability Test

3. Drawing

Unit:mm

Tolerance:

±0.2

4.4 Temperature Cycle Test
Temperature -40°C/+85°C
Temperature Change 1

±2/min

Duration at +85°C 2h(each cycle)
Duration at -40

°C 2h(each cycle)

Duration for one cycle 8h
Cycle 10