Reliability test, 5 0.5h 3h, Transducer – BeStar SMT5050-03H02 LF User Manual

Page 4: 25 c, 55 c

Advertising
background image

3.1 high temperature test

Temperature +80

°C

Duration 240hrs

3.2 low temperature test

Temperature -30

°C

Duration 240hrs

3.3 life test in normal temperature

Temperature 25

±10°C

Power supply 3.0Vo-p square wave 1/2 duty 4kHz
Duration 240hrs

3.4 Thermal shock

Cycles 50

3.5 Humidity cycle test

Cycles 5

+80 C

30min

3.6 High Temp. life

Temp. +70

°C

Power supply 3.0Vo-p Square wave1/2duty 4kHz
Duration 240hrs

3.7Low Temp. life

Temp. -30

°C

Power supply 3.0Vo-p Square wave 1/2duty 4kHz
Duration 240hrs

30min

-30

°C

3.Reliability Test

+25 C

3h

a

b

12.5 0.5h

3h

c

24h

+55 C

a,c :95-100%RH
b : 90-96%RH
Cycles 6

1

2

3

H

G

F

E

D

C

B

2

1

3

Page:3 of 8

A

Transducer

4

5

6

H

G

F

E

D

C

Drawn by:

Date:

B

Note

Approved by:

4

Drawn

5

REV.

6

Date

A

Checked by:

T

h

is

p

ri

n

t

and

i

n

fo

rm

a

ti

on

t

he

re

i

n

a

re

p

rop

ri

e

ta

ry

t

o

B

e

s

ta

r E

le

c

tr

on

ics

I

ndu

s

tr

y

C

o

.,

L

td.

and

s

ha

ll

no

t

be

u

s

ed

i

n

w

ho

le

o

r

in

p

a

rt

w

it

hou

t

it

s

wr

itt

en

c

on

tent

www.be-star.com [email protected]

SMT5050-03H02 LF

A

08/07/09

魏奉玲

08/07/09

陶红仲

BS/TET01.544A

SMT5050-03H02 LF

魏奉玲

张秀琴

Advertising