2.Test Method
Power supply Ampere-meter Buzzer Microphone dB meter
1. Characteristics
No. Item Specification
1. Rated Voltage 12 V
2. Operating Voltage 6...16VDC
3. Current Consumption max17mA
4. a)SPL Level at 1m min 95 dB
5. Resonant Frequency 2.7
0.5KHz
6. Tone Pulse
7
.
Ingress protection IP 20
8. Storage Temperature -25 ...+70
C
9. Operating Temperature -20 ...+65
C
10. Housing material ABS
11. Housing color White/Red/Grey
12. Weight 135g
Note:a) Value applying at rated voltage(DC).
b) On-off cycle:120
±20C/M