Microphone, Reliability test – BeStar BCMMEMS001A-42 LF User Manual

Page 4

Advertising
background image

C

C

Drawn

A

Rev.

6

Date

B

www.be-star.com [email protected]

Approved by:

Checked by:

Note

5

4

Date:

Drawn by:

3

2

A

Page:4 of 8

1

B

T

h

is

p

ri

n

t

a

n

d

i

n

fo

rm

a

tio

n

t

he

re

i

n

a

re

p

ro

p

ri

e

ta

ry

t

o

B

e

s

ta

r

E

le

c

tr

o

n

ics

I

ndu

s

tr

y

C

o

.,

L

td.

a

nd

s

h

a

ll

no

t

b

e

u

s

ed

i

n

w

h

o

le

o

r

in

pa

rt

w

ith

ou

t

it

s

w

ri

tt

en

c

on

tent

D

E

F

G

H

6

5

4

3

2

D

E

F

G

1

H

10.04.27

DRG NO:

4.1. Simulated Reflow (Without solder):

Samples for qualification testing require a minimum of 3 passes of standard reflow
solder profiles .2 hours of setting time is required between each reflow profile test.

4.2. Static Humidity:

Precondition at +25℃ for 1 hour.Then expose to +70℃ with 90 to 95% relative
humidity for 120 hours.Finally dry at room ambient for 3

±1 hours before taking

final measurement.

4.3. Temperature Shock:

Each cycle shall consist of 15 minutes at -40℃,15 minutes at +85℃ with a 20
seconds maximum transition time .Test duration is for 30 cycle , starting from cold

to hot temperature.

4.4. ESD sensitivity:

Perform ESD sensitivity threshold measurements for each contact according to

MIL-STD-883E,Method 3015 for Human Body Model and for Machine Model.
Identify the ESD threshold levels indicating passage of 2000V Human Body
Model.

4.5. Random Vibrations:

Vibrate randomly from 20 Hz to 2000Hz using the Following Power Spectra

Density(PSD) profile: It is a +3dB/octave .Starting with 0.01325g2/ Hz from 20Hz

to 80Hz ,then 0.053g2/ Hz or 8g's RMS level from 80Hz to the PSD tolerance is

±

3dB from 20Hz to 1000Hz and

±6dB above 1000Hz .The analyzer bandwidth to

be set at 25Hz BW from 20Hz to 2000Hz , 50Hz BW to 1000Hz,and finally 100Hz
BW to 2000Hz ,The test time is 15 minutes per plane.

4.6. Mechanical Shock:

Subject samples to half sine shock pulses(3000 g's

±15% for 0.3ms )in each

direction ,totally 6 shocks.

4.7.Operation Life:

Subject samples to +85

for 168 hours under full rated power.

4.8. Solder Reflow:

One pass through standard solder reflow profile.

4.9.Drop Test:
Samples are fixed inside the fixture and droped naturally from the 2m height onto
a concrete plane in six direction for three times ,total 18 times .The dimension of
test fixture is 102 (L)*54(W)*41(H)mm, and the weight is around 200g.
4.10.Sinusoidal Vibration:
Vibrate randomly from 10Hz to 2000Hz ,1 octave/minute with 2mm amplitude
(peak to peak) for 2 hours in each direction.

4.Reliability Test

Microphone

王焕焕

A

BS/TEM01.159A

10.04.27

王焕焕

徐 波

张秀琴

Acoustics & Sensor

BCMMEMS001A-42 LF

BCMMEMS001A-42 LF

Advertising