11.0 Maximum Operating Pressure

MAXIMUM OPERATING PRESSURE FOR DOUBLE ACTING - SINGLE CYLINDER ACTUATOR - Symmetrical Yoke/Canted Yoke

Model

Rated Torq

Cyl

Nm

Lb-in

8

9

10

12

14

16

18

20

22

24

28

45 E2

4,500

39,830

S

150

144

117

81

59

C

150

119

96

67

49

73 E2

7,300

64,612

S

150

107

78

60

C

127

88

65

49

14 E3

14,000

123,914

S

150

127

97

77

62

C

142

104

80

63

51

24 E3

24,000

212,424

S

150

124

98

80

66

55

C

134

102

81

66

54

46

45 E3

45,000

398,295

S

150

121

100

84

62

C

123

100

83

69

51

MAXIMUM OPERATING PRESSURE FOR DOUBLE ACTING - DUAL CYLINDER ACTUATOR - Symmetrical Yoke/Canted Yoke

Model

Rated Torq

Cyl

Nm

Lb-in

8

9

10

12

14

16

18

20

22

24

28

45 E2

4,500

39,830

S

92

72

59

41

C

76

60

48

73 E2

7,300

64,612

S

77

54

C

64

44

14 E3

14,000

123,914

S

87

64

49

C

72

52

40

24 E3

24,000

212,424

S

82

63

49

40

C

67

52

45 E3

45,000

398,295

S

75

61

50

42

C

62

50

41

11.2 DD (Double Acting - Dual Cylinder)