Installation, Before use – BVA Hydraulics J72101 User Manual
Page 3

Figure 1 - Low Profile Cylinder Kit Components
Carrying
Case
Female Coupler
3/8” NPTF
Base
3
inSTaLLaTiOn
iMPOrTanT! Use an approved, high-grade
pipe sealant to seal all hydraulic connections.
1. Remove the dust cover and rubber plug from coupler.
2. Inspect all threads and fittings for signs of wear or damage, and replace as needed.
3. Clean all threads and fittings.
4. Connect hydraulic hose from hydraulic pump to the cylinder coupler. Ensure that there are no fluid leaks.
5. Install in-line pressure gauge.
6. Check for leaks in system and have repaired by qualified personnel.
Note: The use of cylinder attachments or extensions reduces the cylinder capacity by at least 50% per attachment/
extension.
Before operating the pump, tighten all hose connections with proper tools. Do not overtighten.
Connections should only be tightened securely and leak-free. Overtightening can cause premature thread
failure or high pressure fittings to burst.
Before repairs are made, depressurize cylinder.
Tips for hydraulic hoses & fluid transmission lines:
• Avoid short runs of straight line tubing. Straight line runs do not provide for expansion and contraction due to
pressure and/or temperature changes.
• Reduce stress in tube lines. Long tubing runs should be supported by brackets or clips.
BEFOrE USE
1. Before using this product, read the owner's manual completely and familiarize yourself thoroughly with the product,
its components and recognize the hazards associated with its use.
2. Verify that the product and the application are compatible. If in doubt, call BVA Technical Service (888) 332-6419.
3. Inspect before each use. Do not use if bent, broken, leaking or damaged components are noted.
4.
Replace worn or damaged parts and assemblies with BVA Hydraulics authorized replacement parts only. Lubricate
as instructed in Maintenance Section.
5. Ensure method of confirming load is accurate and working properly. Have gauge or load cell accuracy verified by
qualified personnel on a yearly basis.
6. Cylinders should be stored where protected from the elements, abrasive dust, and damage. These cylinders
should be stored in the upright position.
Extension III, 3”
Cylinder
!
!
Extension II, 2”