LIFETIME LIMITED WARRANTY

BVA Hydraulics®, represented in the United States by Shinn Fu Company of America, Inc. [“SFA”] warrants this product

to be free from defects in material and workmanship for the life of the product as long as the original purchaser owns the

product. The warranty is non-transferable and is subject to the terms, exclusions, and limitations described below:
• Damaged components, including but not limited to bent rams, dented or crushed cylinder walls, broken welds or couplers

as well as worn out seals, o-rings and springs are the result of misuse and not covered by warranty and BVA Hydraulics

will not provide any warranty credit for such damaged components.

• This warranty does not cover ordinary wear and tear, overloading, alterations (including repairs or attempted repairs not

performed by BVA Hydraulics or one of its authorized personnel), improper fluid use, or use of the product in any manner

for which the product was not intended or the use of which is not in accordance with the instructions or warnings provided

with the product.

• In the unlikely event that a BVA Hydraulics product fails due to material defect in workmanship, you may contact SFA

for disposition. In such cases, the customer’s sole and exclusive remedy for any breach or alleged breach of warranty is

limited to the repair or replacement of the defective product.

• Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever.

• THIS WARRANTY IS LIMITED TO NEW PRODUCTS SOLD THROUGH AUTHORIZED DISTRIBUTORS AND OTHER

CHANNELS DESIGNATED BY BVA HYDRAULICS. NO AGENT, EMPLOYEE OR OTHER REPRESENTATIVE OF BVA

HYDRAULICS IS AUTHORIZED TO MODIFY THIS WARRANTY.

• THE FOREGOING IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,

INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FOR A FITNESS FOR

A PARTICULAR PURPOSE.

• Components not manufactured by BVA Hydraulics including certain motor systems, gasoline engines, and others are not

covered by this warranty and instead are covered by the manufacturer’s separate manufacturer’s warranty provided in

the package.

• BVA Hydraulics’ liability in all cases is limited to, and will not exceed the purchase price paid for the product.

SFA Companies

10939 N. Pomona Ave. Kansas City, MO 64153

Tel: 888-332-6419

E-mail: [email protected]

TROUBLESHOOTING GUIDE

The following information is intended as an aid in determining if problem exists. Pumps should be repaired only by authorized

BVA Service Center. For repair service, contact service center in your area.

Symptom

Possible Causes

Corrective Action

Erratic application action

• Air in the system

• External leak

• Internal hydraulic leak

• Vent the system

• Tighten all connections

• Contact service center

Application does not extend, move

or respond to pressurized fluid

• Overload condition

• Release valve not closed

• Loose couplers

• Faulty couplers

• Pump malfunction

• Remedy overload condition

• Ensure release valve closed

• Tighten couplers

• Replace couplers

• Contact service center

Application responds to pressurized

fluid, but system does not maintain

pressure

• Overload condition

• Release valve not closed

• Pump or valve malfunction

• Application/connection leaking

• Remedy overload condition

• Ensure release valve closed

• Contact Service Center

• Replace application/connection

Application responds slower than

normal

• Loose connection or coupler

• Restricted hydraulic line or fitting

• Application/connection leaking

• Tighten connection or coupler

• Clean and replace if damaged

• Replace application/connection

Application does not return fluid to

pump (i.e. cylinder will not retract)

• Malfunctioning coupler, damaged

application

• Reservoir overfilled

• Secure load by other means. Depressurize

pump and hose, remove coupler and/or

application, then renew or replace

• Secure load by other means. Depressurize

pump and hose, remove application, then

drain fluid to proper level

Application does not fully extend

(cylinder or spreader)

• Fluid level in pump is low

• Volume of oil is not sufficient to

extend application

• Secure load by other means. Depressurize

pump and hose, remove application, then

fill fluid to proper level

• Secure load as above, then match pump to

application.

Poor performance

• Fluid level in pump is low

• Ensure proper fluid level

8