BVA Hydraulics PEW0501, PEW1002, PEW1503, PEW3005 User Manual
Page 2

2
Save these instructions. For your safety, read and understand the information contained within. The owner and
operator shall have an understanding of this product and safe operating procedures before attempting to use this
product. Make certain that the operator thoroughly understands the inherent dangers associated with the use and
misuse of the product. If any doubt exists as to the safe and proper use of this product as outlined in this factory
authorized manual, remove from service immediately.
Inspect before each use. It is recommended that, prior to each use, an inspection be done by qualified personnel
and that any missing or damaged parts, decals, warning / safety labels or signs be replaced with factory authorized
replacement parts only. Any pump that appears to be damaged in any way, is worn, leaking or operates abnormally
shall be removed from service immediately until such time as repairs can be made. Any pump that has been or
suspected to have been subject to a shock load (a load dropped suddenly, causing the system pressure to exceed
10,000 PSI), shall be removed from service immediately until checked by qualified personnel. Owners and operators
of this equipment shall be aware that the use and subsequent repair of this equipment may require special training and
knowledge. Labels and owners manuals are available from the manufacturer (see Service Parts pages 8 thru 11).
PRODUCT DESCRIPTION
BVA Hydraulics Electric Pumps are engineered to meet or exceed ANSI B30.1 Standards for Performance and Safety.
Its unique hydraulic circuit allows quick displacement of hydraulic fluid under no load conditions and easy pumping in
loaded conditions. These electric hydraulic pumps supply compressed hydraulic fluid to compatible applications i.e.
rams, presses, spreaders, compactors and crimping machines, anywhere that 10,000 PSI of fluid pressure is needed.
Special skill, knowledge and training may be required for a specific task and the product may not be suitable for all the
jobs described above. Unsuitable applications would include applications that call for a device to move, level or support
persons, animals, hazardous materials, mobile homes/ dwellings in general, mirrors and/or plate glass, and/or to
connect/secure hatches, components, etc. between bulkheads. The user must make the decision regarding suitability
of the product for any given task and assume the responsibility of safety for himself and others in the work area.
Note: Always check connections before using. Alteration of these products is strictly prohibited. Use only those
adapters and attachments provided and approved by the manufacturer.
SPECIFICATIONS
Control Valve Handle
Coupler
(not included)
3/8"-18 NPTF
3/8"-18 NPTF
Figure 1 - Typical Control Valve with Couplers
Coupler
(not included)
1st Stage 2nd Stage 1st Stage 2nd Stage
PE0501
PEW0501
1
305
18
0.5
8
PE1002
PEW1002
2
458
37
1
15
PE1503
PEW1503
3
610
61
1.5
17
PE3005
PEW3005
5
793
110
3
230
15
Current
Drawn
(A)
10,000
580
4-way, 3
position
110/115
Output Flow Rate
(in
3
/min)
Valve
Type
Motor
(HP)
Motor
Voltage
(V)
Model
(PE
series)
Model
(PEW
series)
Usable
Oil
Capacity
(gal)
Rated Pressure