BEFORE USE

1. Before using this product, read the instruction manual

completely and familiarize yourself thoroughly with the

product, its components and recognize the hazards

associated with its use.

2. Verify that the product and the application are compatible.

Inspect before each use. Do not use if bent, broken, leaking

or damaged components are noted.

3. Replace worn or damaged parts and assemblies with

BVA Hydraulics Authorized Replacement Parts only (See

Replacement Parts Section). Lubricate as instructed in

Maintenance Section.

4.Ensure method of confirming load is accurate and working

properly. Have gauge or load cell accuracy verified by

qualified personnel on a yearly basis.

5.Pumps should be stored where protected from the elements,

abrasive dust, and damage. Pumps can be stored

horizontally or vertically.

SET UP

NOTICE: The pump’s maximum working pressure is 10,000

PSI. Make sure that all hydraulic equipment such as cylinders,

hoses, couplers and etc. used with this pump are rated at

10,000 PSI operating pressure or more.

1. Prepare the pump for use:

A) For models P1201 & P1201S:

Remove shipping plug and replace with a vent plug. Pull

vent plug stem upward before use, press down when

moving or storing the pump. (refer to Figure 4)

B) For models P2301, P2301M & P4301:

Turn the top cap of the vent screw counter-clockwise to

open the vent. Turn the cap clockwise to close the vent

screw when moving or storage. (refer to Figure 5)

2. Carefully remove the threaded plug on oil outlet port, then

connect 3/8”NPTF hydraulic connection to oil outlet port,

i.e. coupler, hydraulic hose, fitting etc.

For model P2301M:

The pump comes with a 4-way valve to use with double

acting cylinder. Connect two hoses from the pump to both

ports of a double-acting cylinder. If using on single acting

cylinder, the valve needs to be changed to 3-way valve.

Consult with BVA Technical service 888-332-6419.

NOTICE:

Always secure threaded connections with non-

hardening pipe thread compound. Take care not to introduce

compound into port orifices. Tighten securely to prevent

accidental removal of components while in use.

3. Install a pressure gauge in-line from the pump for better

control and safety purpose.

4. Tighten securely to prevent accidental removal of

components while in use.

5. Check for leaks in system and repair by qualified personnel

as needed. Depressurize the hydraulic system before

servicing.

4

Figure 5

- Prepare to use Illustration for P2301,

P2301M & P4301

Remove shipping plug and replace with air vent

plug (included) before initial use.

Pull stem upward before use, press down when

moving or storing pump.

Figure 4

- Prepare to use Illustration for P1201 & P1201S

Turn the top cap counter-clockwise to open the

vent before use.