Model battery types mv tv f – BatteryMINDer 12118 User Manual
Page 9
 
Rev. C-011011
Page
P/N VDC121PlusSeriesMNL
BatteryMINDer Plus
Models 12106 / 12106A8V / 12117 / 12118
VOLTAGE TABLE
MV:	 Minimum	Voltage	of	a	battery	the	unit	will	accept.
TV:		 Trip	Voltage	to	move	from	Constant	Current	stage	into	Float	stage.
F:	 	 Voltage	during	the	Float	stage.
Model
Battery Types
MV
TV
F
12106
6V Lead-Acid
5.5V
7.2V
6.7V
12106A8V
8V Lead-Acid
7V
9.8V
9V
12117
12V Lead-Acid
10.5V
14.4V
13.4V
12118
12V AGM Specific
(Optima, Odyssey, etc.)
10.5V
14.7V
13.6V
CHARGING / MAINTAINING MULTIPLE BATTERIES
To	properly	charge	or	maintain	multiple	batteries	they	should	all	be	the	same	type	
(gel,	flooded	or	AGM)	and	condition.		It	is	OK	to	mix	deep	cycle	and	starter.		Charge	
each	battery	individually	before	connecting	together.		
Never connect batteries at
different	states	of	charge.		The	charged	battery	will	rapidly	transfer	energy	to	the	
discharged	battery	possibly	causing	catastrophic	failure.	
Once	 the	 batteries	 are	 charged,	 use	 18	 gauge	 or	 greater	 wire	 to	 connect	 the	
batteries.		
If	 connecting	 multiple	 batteries	 of	 the	
same	 voltage,	 wire	 them	 in	 parallel	
(BatteryMINDer	positive	to	positive	A	to	
positive	 B,	 BatteryMINDer	 negative	 to	
negative	 A	 to	 negative	 B).	 	 This	 is	 the	
same	 type	 of	 connection	 you	 would	 use	
when	jumping	a	car	(in	fact,	jumper	cables	
are	great	for	this).	
12V
+
–
12V
+
–
TO CHARGER
+
TO CHARGER –
Parallel Connection Diagram
(12V System using Two 12V Batteries)
Con’t. on next page