BRAND Hydraulics HP STYLE HAND OPERATED PUMPS User Manual

Revision 05-12, Keep with product until installed

Advertising
background image

B

Certificate #02.002.1

ISO 9001:2000 WITH DESIGN


Revision 05-12

1.84"

[46.7]

1.48"

[37.7]

1/4" NPT RETURN PORT

(RP, OPTIONAL)

YD

ICS

3.25"

[82.5]

3.41" [86.6]

4.05" [103.0]

4.05" [103.0]

3.50" [88.9]

3.25" [82.5]

4X Ш0

.28" [Ш7

.1]

#6 SAE OUTLET

50 CU. IN.

65 CU. IN.

80 CU. IN.

95 CU. IN.

6"

[1

52.4]

2"

[5

0.8]

8"

[2

03.2]

10

"[

254]

12

"[

304

.8]

OUTLET

20

"[

508]

RELEASE VALVE

FILL PLUG

(1/4" NPT)

BODY

TANK

COVER

TL (1/4" NPT PORT)

ADJUSTABLE RELIEF

6.

75

"

[171.5]

3/4" PIPE

DIMENSIONS LISTED ARE THE SAME FOR ALL THREE PUMP SERIES
(HP61DA SHOWN)

BRA

S.N.

P.N.

INSTALLATION SHEET FOR

HP STYLE HAND OPERATED PUMPS

KEEP WITH PRODUCT UNTIL INSTALLED

ADDITIONAL SHEETS MAY BE PRINTED OUT FROM OUR WEBSITE

WWW.BRAND-HYD.COM

UNDER PRODUCT CATALOG SECTION


Can I paint my pump? – Painting valves is okay as long as the all ports are properly plugged and piston is masked.

Pump will not pump – First, make sure the release valve is closed. After that, make sure the relief setting is high enough for
the application.

How do I adjust the relief? – Begin by loosening the 9/16” [14.3mm] nut; then using a 5/32” [4.0mm] Allen wrench, turn the
screw clockwise to increase the pressure. One (1) full turn is ~1000psi [68.9 bars].

What is my Hand Pump relief factory setting? – The settings are:

HP121 – 2,000psi [137.9 bar]

HP61 – 3,000psi [206.8 bar]

HP22 – 4,000psi [275.8 bar]

Figure 1: Dimensional Data for HP style hand pumps in inches & [millimeters].