4-Port 6Gb/s Mini-SAS Backplane 80H10321516A1
User’s Manual

15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,

Tel: +886 2 82265500 Fax: +886 2 82265392 Email: [email protected]

6

w
w
w
.

c
h
e
n
b
r

o
.

c
o
m

Backplane Layout

Backplane Connectors

(1)

[CN11 / CN21 / CN31 / CN41]

: Connect to 22-pin SATA-II or 29-pin SAS HDD

(2)

[JF1 / JF2 / JF3 / JF4 / JF5]

: Fan connectors 1~5

(3)

[CN2]

: HDD Failure LED Signal Pin Header

Connect the 4-pin HDD LED cable (26H113322-001) from CN2 to the CATHODE

of the HDD failure connector on RAID card. Refer to the RAID card’s user

manual for the detail pin definition.

(4)

[CN3]

: Reserved for factory use only

(5)

[CN4]

: Backplane ID setting jumper

(6)

[CN5]

: Signal connector (Board to Board Connection)

(7)

[CN6 / CN7]

: 4-pin Power connectors

(8)

[CN8]

: Reserved for factory use only

(9)

[CN10]

: SGPIO HDD fail function jumper

Jumper Closed: Enable SGPIO HDD Failure Signal (Default)

Jumper Opened: Disable SGPIO HDD Failure Signal

(10)

[CN12]

: Auto Detection Jumper For SAS or SATA HDD

Jumper Closed: Enable Auto Detection (Default)

Jumper Opened: Disable Auto Detection

(11)

[CN1]

: Mini-SAS connector

Rear View

Front View

CN2

CN4 CN3

JF1

CN1

CN41

CN31

CN21

CN11

CN5

CN7

CN6

CN10

CN12

Jumper
Setting

Close

Pin 1 & 2

Close

Pin 3 & 4

Close

Pin 5 & 6

Close

Pin 7 & 8

Close

Pin 9 & 10

Close

Pin 11 & 12

Backplane
ID

1

2

3

4

5

6

CN8

JF2 JF3

JF4 JF5

HDD 1

D 2

HDD 2

HDD 3

HDD 3

HDD 4