12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1
User’s Manual
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: [email protected]
9
w
w
w
.
c
h
e
n
b
r
o
.
c
o
m
SW1 FUNCTION
SW1-1: FAN1 Monitor Enable/Disable Setting
Sw1-1
FAN1
ON
Enable
OFF
Disable (Default)
SW1-2: FAN2 Monitor Enable/Disable Setting
Sw1-2
FAN2
ON
Enable (Default)
OFF
Disable
SW1-3: FAN3 Monitor Enable/Disable Setting
Sw1-3
FAN3
ON
Enable (Default)
OFF
Disable
SW1-4: FAN4 Monitor Enable/Disable Setting
Sw1-4
FAN4
ON
Enable (Default)
OFF
Disable
SW1-5: MB PWM Monitor Enable/Disable Setting
Sw1-5
MB PWM
ON
Enable
OFF
Disable (Default)
SW1-6: TEMP Threshold Setting
Sw1-6
TEMP
ON
55
℃
℃
℃
℃
(Default)
OFF
65
℃
℃
℃
℃