SECTION 5: Adjustments (continued)
5.2.1.3.
Trip the internal clutch, the L.E.D. should now go off. Repeat this
process several times making a full revolution of the output, the L.E.D.
must go off consistently when the clutch is tripped and light when the
clutch is reset.
NOTE: The detection switch set up procedure is appropriate for the
Industrial Motion Control (Turck) part numbers listed below. If your
equipment has another model number or is from another
manufacturer, contact the switch manufacturer for set up
procedures.
Industrial Motion Control PN 1000000938 (Turck # Bi 1-G08-AN6X)
Industrial Motion Control PN 1000000939 (Turck # Bi 2-G12-AN6X)
Industrial Motion Control PN 1000003115 (Turck # Bi 1-G08-AN6X-H1341)