21

SECTION 5: Adjustments (continued)

5.2.1.3.

Trip the internal clutch, the L.E.D. should now go off. Repeat this

process several times making a full revolution of the output, the L.E.D.

must go off consistently when the clutch is tripped and light when the

clutch is reset.

NOTE: The detection switch set up procedure is appropriate for the

Industrial Motion Control (Turck) part numbers listed below. If your

equipment has another model number or is from another

manufacturer, contact the switch manufacturer for set up

procedures.

Industrial Motion Control PN 1000000938 (Turck # Bi 1-G08-AN6X)

Industrial Motion Control PN 1000000939 (Turck # Bi 2-G12-AN6X)

Industrial Motion Control PN 1000003115 (Turck # Bi 1-G08-AN6X-H1341)

Advertising