Filters and maintenance – Neff D4982X0 User Manual

Page 24

Advertising
background image

24

Removing the filter:

Warning: The halogen bulbs must be
switched off and cool.

1. Remove the metal-mesh filters.

2. Depress the catches on both sides of

the filter and remove the activated
carbon filter.

3. Replacing the activated carbon filter:

❑ A replacement filter can be obtained

from any authorized dealer
(see optional accessories).

❑ Use original filters only.

This will ensure maximum
performance.

4. Insert the grease filters.

Disposing of the old activated carbon
filter:
❑ Activated carbon filters do not contain

any pollutants and can be disposed of
with domestic refuse.

Filters and maintenance

3. Engage the catches at both sides.

4. Insert the metal-mesh grease filters (see

”Removing and inserting the metal-mesh
grease filters”).

5. Cancel the

ã

display.

❑ Press the

L

button for at least

3 seconds.
The

ã

display then goes out.

Saturation indicator:

When the activated carbon filter is satura-
ted, an acoustic signal is emitted for 6
seconds when the fan has switched off and

ã

is displayed. The activated carbon filter

should then be replaced immediately.

Activated carbon filter:

For neutralizing odours in recirculating
mode.

Caution:

As the filter becomes more and more
saturated with grease, there is an increased
risk of fire and the function of the extractor
hood may be impaired.

Important:

Change the activated carbon filter promptly
to prevent the risk of fire from the
accumulation of heat when deep-fat frying
or roasting.

Inserting the filter:

Warning: The halogen bulbs must be
switched off and cool.

1. Remove the metal filters

(see "Removing and inserting the metal
grease filters").

2. Insert the activated carbon filter.

Advertising