ASB Heating Elements Ltd. 2” NPT Screw Plug Immersion Heater User Manual

2” npt screw plug immersion heater, Two element design - one phase only, Standard (sp series)

Advertising
background image

5

1/4"

ap

pro

x.

2

3/4"

1

1/4"

NPT opening

5

1/4"

4

1/4"

dia.

3"

ap

pro

x.

2

5/16"

1" NPT opening

4

1/2"

3

1/2"

dia.

Figure 70

5

5/16

"

ap

pro

x.

3

13/16

"

1

1/2"

NPT opening

6

13/16"

5

3/4"

dia.

2

13

/

16

"

3

1/2

"

4

1/8

"

4

3/4

"

4

5/16

"

4

1/4

"

2” NPT Screw Plug Immersion Heater

Two element design - one phase only

Standard (SP series)

General Purpose Enclosure - no thermostat

With thermostat (ASP series)

General Purpose Enclosure - with thermostat

Moisture Resistant or Hazardous Location

Moisture Resistant or Hazardous Location - ASP series

with any optional thermostat

50-60 watts/in

2

Copper Sheath

Typically to heat:

2” brass screw plug

municipal water

2 elements - up to 600 volts 1 phase

(specifiy voltage when ordering)

watts

immersed

catalogue number

net

length

Fig. 67

Fig. 68

weight

B dim.

standard

with thermostat

(lb)

1500

6

1

/

2

SPC-2015

ASPC-2015

6

2000

7

1

/

2

SPC-2020

ASPC-2020

6

2500

9

1

/

2

SPC-2025

ASPC-2025

6

3000

11

1

/

2

SPC-2030

ASPC-2030

7

4000

17

3

/

4

SPC-2040

ASPC-2040

7

5000

19

SPC-2050

ASPC-2050

7

6000

24

1

/

2

SPC-2060

ASPC-2060

8

7000

28

SPC-2070

ASPC-2070

8

8000

32

1

/

2

SPC-2080

ASPC-2080

9

10000

39

3

/

8

SPC-2100

ASPC-2100

9

12000

47

1

/

4

SPC-2120

ASPC-2120

10

15000

54

SPC-2150

ASPC-2150

10

watts

immersed

catalogue number

net

length

Fig. 67

Fig. 68

weight

B dim.

standard

with thermostat

(lb)

1500

6

1

/

2

SPI-2015

ASPI-2015

6

2000

7

1

/

2

SPI-2020

ASPI-2020

6

2500

9

1

/

2

SPI-2025

ASPI-2025

6

3000

11

1

/

2

SPI-2030

ASPI-2030

7

4000

17

3

/

4

SPI-2040

ASPI-2040

7

5000

19

SPI-2050

ASPI-2050

7

6000

24

1

/

2

SPI-2060

ASPI-2060

8

7000

28

SPI-2070

ASPI-2070

8

8000

32

1

/

2

SPI-2080

ASPI-2080

9

10000

39

3

/

8

SPI-2100

ASPI-2100

9

12000

47

1

/

4

SPI-2120

ASPI-2120

10

15000

54

SPI-2150

ASPI-2150

10

watts

immersed

catalogue number

net

length

Fig. 67

Fig. 68

weight

B dim.

standard

with thermostat

(lb)

1500

6

1

/

2

SPS-2015

ASPS-2015

6

2000

7

1

/

2

SPS-2020

ASPS-2020

6

2500

9

1

/

2

SPS-2025

ASPS-2025

6

3000

11

1

/

2

SPS-2030

ASPS-2030

7

4000

17

3

/

4

SPS-2040

ASPS-2040

7

5000

19

SPS-2050

ASPS-2050

7

6000

24

1

/

2

SPS-2060

ASPS-2060

8

7000

28

SPS-2070

ASPS-2070

8

8000

32

1

/

2

SPS-2080

ASPS-2080

9

10000

39

3

/

8

SPS-2100

ASPS-2100

9

12000

47

1

/

4

SPS-2120

ASPS-2120

10

15000

54

SPS-2150

ASPS-2150

10

50-60 watts/in

2

Incoloy

Typically to heat:

2”316 SS screw plug

municipal water

2 elements - up to 600 volts 1 phase

process water

(specifiy voltage when ordering)

50-60 watts/in

2

316 SS Sheath

Typically to heat:

2”316 SS screw plug

food processing

2 elements - up to 600 volts 1 phase

de-ionized water

(specifiy voltage when ordering)

mild acid solution

Moisture Resistant Enclosure (add suffix MR)
Hazardous Location (Explosion Resistant add suffix ER)
Non-Thermostat version - (NEMA 4 or NEMA 7)

Moisture Resistant Enclosure (add suffix MR)
Hazardous Location (Explosion Resistant add suffix ER)
DPST or TPST
(NEMA 4 or NEMA 7)

10 - 120°C (50 - 250°F)
240 vac, 25 amp, SPST

Figure 67

Figure 68

Figure 69

B3

Optional Thermostats

Available temperature ranges and/or electrical choices

Temperature ranges

Electrical ranges

-16 to + 40°C (0-100°F)

240 vac, 25 amp, DPST

70 - 280°C (160 - 540°F)

480 vac, 15 amp, TPST

160 - 370°C (320-700°F)

600 vac, 15 amp, TPST

ASP series

Built-in Thermostat SPST

(NEMA 4 or NEMA 7)

SP series

Figure 71

Advertising