C.E. Niehoff & Co. N7485 DE Housing Replacement Instructions User Manual

N7485 drive end housing on

Advertising
background image

N7485 Drive End Housing on

CEN P/N N1506-1

Field Replacement Instructions

Figure 1 — Through-stud Removal

When replacing the drive end housing on the N1506-1 alternator, follow Figure 1 to remove the
proper through-stud on drive end of shell/stator/fi eld coil assembly.

The new N7485 drive end housing has molded B+ studs and will require the through-stud shown in Figure 1
to be removed to fit the new housing.

Use caution when removing through-stud to prevent damaging stator windings.

CAUTION

II0107A

T

T

Remove this through-stud ONLY

Page 1 of 2

Go to Page 2 and Figure 2 to set new drive end housing in position.

T

T

Position center

drain hole facing you

Advertising