Lbcd dynamic tests – C.E. Niehoff & Co. LBCD Static/Dynamic Troubleshooting Guides User Manual
Page 2

TG53B
Page 2 of 2
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
LBCD DYNAMIC Tests
(Static Tests on Page 1)
Start
Steady AMBER
Read RPM
Charging system indicator
LED is “OFF.”
Wait ten seconds.
Yes
No
Is RPM greater than 1500?
Read System Voltage
Yes
No
Is System Voltage less than 20.5 V?
Steady GREEN.
System is operating
properly.
Steady RED
Read Alternator Voltage
Yes
No
Is Alternator Voltage less than 24 V?
Trickle charge
“ON.”
Trickle charge
“OFF.”
Read Battery Voltage
Yes
No
Is Battery Voltage more than 24.5 V
for one time and one time only?
Batteries are reconnected.
Steady GREEN.
System is operating properly.
MASTER SWITCH ON, KEY ON, ENGINE ON
Batteries are disconnected.
Steady RED
Yes
No
Are batteries disconnected?
LBCD is defective. Replace.
Connect batteries and
then go back to
“Read System Voltage”
above