6.3 Tightening Bracket Bolts

The bottom bracket is held to the aluminium clamp bar by two bolts. If either of these bolts is

loose or slightly tweaked out of shape, the pneumatic seal won’t hold. It is important that these

bolts be tight.

LOWER BRACKET 

BOLT 

BRACKET ARM 

SEAL

Warning:

Bottom Bracket bolts are tapped directly into the aluminium. If they are over-

tightened they may strip out the arm.

1. Check that the bolts on the bottom bracket are tight.

2. If the seal still leaks turn off the air, remove the bolts and apply thread sealant before re-

installing them.

3. Make sure that BOTH bolts are tight. If they are not then the bracket will not sit flush.

6.4 Removing the Cylinder

TENSION SCREW

WEAR STRIP 

SCREWS 

1. Turn off the air and remove the airline for the

cylinder to be rebuilt. The line is connected to

the cylinder by a push-in fitting. Simply push

the outer ring in as you pull the airline.

2. Loosen the tension screw on the side of the Cylinder Channel.

3. Remove the (4) Wear Strip screws on each side of the Cylinder Channel and remove the

complete cylinder assembly off the arm.