FLAT BEER


Foamy head disappears quickly: beer lacks usual zestful brewery fresh flavor.

Causes

Corrections

1)

?

Greasy glass

1)

?

Do not wash beer glasses together with glasses
that have contained milk or any other fatty
substance. Lipstick is a fatty substance.. Make
sure it is removed from glass.

?

Excess amount of germicides build up and leave
a fatty film on glass, which may cause flat beer.

?

It is preferable to steam and sterilize glasses
where health laws permit.

?

Wash glasses thoroughly with a good detergent.

?

Do not use soap.

?

Do not dry-wipe glasses. Permit glasses to air-
dry by placing them on wire or corrugated metal.

?

Rinse in fresh cold water just before serving
beer. It is best to serve beer in a wet glass.

2)

?

Improper drawing of beer into glass.

2)

?

Open faucet quickly and completely.

?

Check and find the correct distance to hold
glass from faucet when drawing. Proper foam
should be a tight creamy head, and the collar on
the average glass should be ¾” to 1” high.

?

Beer drawn without head has appearance of
being flat.

3)

?

Not enough pressure.

3)

?

Increase pressure if beer runs too slowly.
Correct flow is to fill

4)

?

Defective Thomas and Tongue Vents.

?

Pressure is shut off.

4)

?

Check all washers frequently, particularly the air
vents. A clogged vent will obstruct the flow of air
or Co2.

?

Check source of pressure. Check power source
when air compressor is used. Air compressor
should never be connected to light switch. Make
certain to have a separate electric plug outlet for
the compressor.

?

Check CO

2

tank, if empty, replace (See inside

cover for proper procedure).

?

When barrel is tapped, and proper pressure
applied, pressure must always remain on until
barrel is empty.

?

If beer is started without first applying pressure
beer will be wild at the start, and flat towards the
end.

5)

?

Pre-color, or beer system, too cold.

5)

?

With an accurate thermometer, check
temperature in pre-cooler or box.

?

Temperature at the faucet should always be
colder by at least two degrees than at the
pre cooler or box.

6)

?

Sluggish pressure regulators.

6)

?

A regular seat, or the regulator diaphragm, may
require replacing.

?

Also, check the same as you would for
Corrections 3 & 4.