Air supply and flue gas discharge

Release R.1.3 UK

29

is

3.9.2

Concentric roof flue terminal

A.O. Smith Water Products Company prescribes the roof flue terminal
(installation type C33) as specified in

Table 3.9

.

IMD-0004

Figure 3.5 Roof flue terminal

Table 3.9 Concentric roof flue terminal specifications

Specification

Description

Manufacturer

Muelink & Grol

Model

M2000 DDV SEC HR

(1)

1.

The model M2000 DDV SEC HR is a special version of the Mugro 3000 series. No other
roof flue terminal may be used, as the BFC- appliance is approved exclusively for this
model of roof flue terminal. You can order the roof flue terminal from A.O. Smith or your
trade supplier, by specifying model: M2000 DDV SEC HR.

Pipe material, flue gas

discharge

Thick-walled lip ring seal

Pipe material, air intake

Thin-walled galvanised sheet steel

Pipe diameter

Concentric

BFC 28: 80/125 mm.

BFC 30, 50 and 60: Ø 100/150 mm.