Meets or exceeds ASHRAE/IES 90.1 b-1989 (1992 requirements)
Standards.
FEATURES
ALL NON-FERROUS WATERWAYS - All heat exchanger waterways 
are 100% copper and bronze. Heavy duty bronze castings and copper 
heat exchanger tubes. Immune to thermal shock. Ideal for hydronic 
applications.
OPTIMUM ENERGY HEAT TRANSFER - Double row integral finned 
copper heat exchanger provides maximum heat transfer. A. O. 
Smith’s self-baffling staggered tube design, assures up to 82% 
thermal efficiency.
BRONZE REMOVABLE RETURN BENDS - Easily removable, these 
allow access and Inspection of individual tubes. These bronze return 
bends offer the optimum protection against corrosion or rust found 
in cast iron headers.
GASKETLESS WET SECTION - Unique “o” ring design compresses 
and forms a water tight seal outside and away from the combustion 
chamber. This isolation allows for years of trouble-free service 
without gasket leaks.
DURAMAX STAINLESS STEEL BURNERS - Reliable, safe and 
quiet. Protects against corrosion and deterioration found with 
aluminized burners. Easy slide out burner tray.
LOW-PROFILE DESIGN - Draft diverter is built-in to provide extra 
clearances for those tight retrofit applications. Certified by A.G.A./ 
C.G.A.
AUTOMATIC SAFE CONTROLS - Highest quality controls assure 
dependable operation, require practically no attention. Safety shutoff 
of pilot and main burners in the event of pilot failure.
INTERMITTENT IGNITION - Standard on all Dura-Max.
COMPACT DESIGN - This rugged unit incorporates a clean, compact
jacket design. Allows for easy access and disassembly. Cool to the
touch. Approved for combustible floor installations. Gas train is
enclosed inside the cabinet.
OTHER FEATURES
• Manual reset high limit • ASME rated pressure relief valve 50# 
(345 kPa) • Factory installed safety flow switch • Redundant safety 
gas valve • On/Off switch with indicator light.
OPTIONS
• Thermal Balancer Pump Delay • Panel mounted Inlet/outlet dial 
thermometers and pressure gauge • Modulation or dual stage firing
• 
Right end gas and/or water connections • Cupro-Nickel Heat
Exchanger • Side Wall Vent Kits.
CERTIFICATION - A.G.A., C.G.A., FM, ASME 160 psi (1100 kPa).
If the heat exchanger should fail within 10 years, 
under the terms of the warranty, A. O. Smith will 
furnish a replacement part; installation, labor,
handling and local delivery extra. THIS OUTLINE 
IS NOT A WARRANTY. For complete information, 
consult the written warranty or A. O. Smith Water 
Products Company.
Warranty does not apply to product installed outside 
of the United States of America or its territorial 
possessions and Canada.