4 isolating transformer, 5 continuous pump, 6 program-controlled pump – A.O. Smith BFC - 28 User Manual

Page 32: 7 extra on mode switch (“tank on”), Isolating transformer, Continuous pump, Program-controlled pump, Extra on mode switch (“tank on”), T. see

Advertising
background image

Installation

32

Instruction Manual BFC

3

is

4. Connect the power cord to the main switch.

Warning

Leave the appliance disconnected until you are ready to start it up.

5. If you do not need to make any more connections:

-

Fit the cap on the electrical connection block.

-

Fit the plastic covers onto the appliance.

3.10.4

Isolating Transformer

An isolating transformer should be used if there is a case of “floating neutral”.
1. Refer to fitting instructions provided with the isolating transformer

(1)

.

2. Connect phase (L), neutral (N) and earth (

A

) of the power cables to

terminals 16 through 21 of the connector block as indicated in

Table 3.10

.

3. Fit the cables in the pull relief.
4. If you do not need to make any more connections:

-

Fit the cap on the electrical connection block.

-

Fit the plastic covers onto the appliance.

5. Connect the power cord to the main switch.

3.10.5

Continuous pump

The continuous pump will start up as soon as mains power is connected to the
appliance.
1. Connect phase (L), neutral (N) and earth (

A

) to terminals 7, 8 and 9 as

indicated in

Table 3.10

.

2. Fit the cable in the pull relief.
3. If you do not need to make any more connections:

-

Fit the cap on the electrical connection block.

-

Fit the plastic covers onto the appliance.

3.10.6

program-controlled pump

Switching on of the program-controlled pump is determined by settings of the
ThermoControl.
1. Connect phase (L), neutral (N) and earth (

A

to terminals 10, 11 and 12 as

indicated in

Table 3.10

.

2. Fit the cable in the pull relief.
3. If you do not need to make any more connections:

-

Fit the cap on the electrical connection block.

-

Fit the plastic covers onto the appliance.

3.10.7

Extra ON mode switch (“Tank ON”)

Tank ON is a facility for connecting an external ON/OFF switch. In the OFF
position, the programmed operating mode is active. In the ON position, the
programmed operating mode is overruled, and the “ON mode” is active.
1. Connect cables (X

1

and X

2

) to terminals 5 and 6 as indicated in

Table 3.10

.

2. Fit the cable in the pull relief.

1.

Contact A.O. Smith for details of the correct isolating transformer.

Advertising