10 troubleshooting, 1 introduction, Troubleshooting – A.O. Smith BFC - 28 User Manual

Page 69: Introduction

Advertising
background image

Release R.1.3 UK

69

10

Troubleshooting

10.1 Introduction

A distinction is made between:

General errors
General errors are not reported on the display. General errors are:
-

Gas smell

-

Display does not light up

-

Insufficient or no hot water.

-

Water leakage

-

Explosive ignition

Table 10.1

gives a troubleshooting overview for general errors.

Displayed errors
Errors are reported on the display, as follows:
-

Line 1: An error code and its short description. The code is made up
of a letter and two digits.

-

Lines 2, 3 and 4: a long description, and a recommended action,
alternating every 2 seconds. See

Figure 10.1

and

Figure 10.2

.

The displayed errors are divided into two groups:
There are various types of errors:
-

LOCK OUT ERRORS
When the cause is no longer present, these errors require a reset with
the R button, before the appliance can resume running.

-

BLOCKING ERRORS
These errors disappear automatically once the cause of the error has
been removed, after which the appliance resumes by itself.

Table 10.2

gives a troubleshooting overview for the errors that appear on the

display.

n

Remark

Footnotes referred to from within any table are shown at the bottom of the
last page of that table.

S02: SENSOR ERROR

TOP TANK

SENSOR 1

NOT CONNECTED

Figure 10.1 Possible error

S02: SENSOR ERROR

TOP TANK

CHECK TOP TANK

SENSOR

Figure 10.2 Action

gis

Advertising
This manual is related to the following products: