Alto-Shaam AS F-60G User Manual

Page 17

Advertising
background image

Gas Fryer Operation & Care Manual • 16

O P E R A T I O N

NOTE:

Perform an initial Boil-Out to clean and
sanitize the fryer station before
operating. (See page 14.)

1.

Service is to be performed by an authorized

Alto-Shaam service agent.

2.

Ensure all local electrical codes, fire codes, and all

other requirements such as hood installation have

been met in the process of installation.

NOTE:

Because each fryer station is controlled
separately, the following procedures
must be followed for every component
fryer in multiple-station units.

3.

Open front access door and ensure drain valve is

closed. The handle should be rotated clockwise until

it stops.

4.

Fill frypot with frying compound as indicated.

(

SEE

ILLUSTRATION ON THE OIL

/

SHORTENING REQUIREMENTS PAGE

)

5.

The Master Power Switch is located behind the front

access door. Turn Master Power Switch “ON.”

6.

Press ELEMENT HI RESET button.

7.

The LED display on the basic control panel will

indicate “-AS-”, the software version, and then “CY”.

8.

When the fryer has reached 135°F, the melt cycle is

complete and the LED display on the control panel

will indicate “HEAt”.

9.

When the fryer displays the set-point temperature,

product can be fried.

10.

More detailed operating guidelines along with

information on programming are located within this

manual.

11.

To shutdown the fryer, turn the Master Power Switch

located behind the front access door to the “OFF”

position.

NOTE:

FOR

YOUR

PROTECTION

The fryer station is

furnished with a hi-limit safety shutoff that will

disengage the control if the frying compound

temperature in the frypot would ever exceed

415°F (213°C). The LED will display “Hi”, the

heat will shut off, the timer will be cancelled, and

a constant alarm will sound. In this event, allow

the frying compound temperature to drop below

415°F (213°C). Open the front access door and

press the OIL HI-LIMIT RESET button for a

period of 3-seconds to restart the control.

S T A R T U P & G E N E R A L O P E R A T I O N

D A N G E R

BEFORE STARTING THE
APPLIANCE, MAKE CERTAIN
YOU DO NOT DETECT THE
ODOR OF GAS.

IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open flame.
• Use a telephone OUTSIDE THE

PROPERTY & IMMEDIATELY
contact your gas supplier.

• If unable to contact your gas supplier,

contact the fire department.

Advertising