Hunter 23855 52 Classic Original User Manual

Installation in concrete ceiling, Installation, The inside story

Advertising
background image

Installation in concrete ceiling

CAUTION:

For concrete mounting, the drilled hole must be recommend-
ed by the manufacturer of the anchor (this is usually marked
on the anchor) and must be drilled at least

1

/

2

" deeper than

the length of the anchor.

The holes must be made with a suitable carbide-tipped
masonry drill bit.

The anchors must be new and unused.

The concrete ceiling must be sound and free of cracks or
voids in the vicinity of the mounting holes.

The anchors must be set in flush with the surface of the
concrete.

The bracket screws must never be backed out. If the bracket
screws can be turned easily (by hand), do not hang fan.

Installation

Drill holes 2" deep in concrete ceiling to receive

1

/

4

" x 1

1

/

2

"

expansion shield anchor, “Rawl No. 1055” or equal. (Not fur-
nished.) Install shield in holes, observing all cautions above.

Proceed with the installation of the fan per the basic installa-
tion instructions.

The Inside Story

Oil is constantly pumped up the spiral groove to lubricate the

rotor and shaft. The oil is returned to the reservoir where the
bearings are submerged in a bath of oil.

This unique lubrication system is built into all Original Hunter

Ceiling Fans. That’s one reason Hunters last so long. And why
we can offer a Limited Lifetime Warranty.

Fill in the blanks below for your record.

Serial number

Model number

Date purchased

Date installed

Dealer/store name where purchased

4

41121-01 9/95

Trouble shooting guide

Problem

Probable Cause

Solution

1. Nothing

1. Power turned

1. Turn power on or

happens;

off or fuse

replace fuse.

blades do

blown.

not rotate.*

2. Loose wire

2. Loosen canopy.

connections

Check all

or wrong

connections (turn

connections.

power off while
checking).

3. Pull chain

3. Pull switch cord.

switch not
“on”.

4. Reversing

4. Slide reversing

switch in

switch either up or

center.

down.

* Note: If blades will not turn by hand, contact your nearest

service representative or dealer.

1. Noisy

1. Blade irons

1. Tighten screws until

operation.

loosely

snug.

screwed to
rotor.

2. Blade

2. Tighten.

screwed
loosely to
blade iron.

3. Blade cracked.

3. Replace all 4 blades.

Contact dealer.

4. Canopy

4. Lower canopy.

contacting
ceiling.

5. No oil or low

5. Check oil level.

oil level.

1. Excessive

1. Unbalanced

1. Rebalance (See

wobbling

blades.

Step 7D).

2. Inadequate

2. Relocate fan.

blade
clearance.

3. Loose blades

3. Tighten all screws.

or blade irons.

4. Fan not

4. Turn power off.

secure on

Support fan very

hanger

carefully. Loosen

assembly.

canopy and hang
correctly.

1.

2.

3.

4.

5.

6.

A.

B.

HUNTER FAN COMPANY
2 5 0 0 F R I S C O A V E N U E
M E M P H I S , T N 3 8 1 1 4

®

Fig. 18

Hanger

Bracket

Bracket

Power

Leads

Used With

Light Kit

Canopy

Set Screw

Oil Filler Hole

Oil Return

Rotor

Field

Windings

Oil Reservoir

Bearing Nut

Switch Housing Cover

Bushing Pin

Ground Screw

Pipe Nipple (Std.)

Shaft

Cast Iron

Fan Housing

Cast Metal

Lower

Cover

Spiral

Groove

Bearings

Switch Housing

Pull Chain
Switch

expansion
shield anchor
set flush with
ceiling (anchor
not furnished)

Concrete ceiling

Bracket
(Furnished with fan)

Fig. 17

Advertising
This manual is related to the following products: