42672-01 • 12/10/08 • Hunter Fan Company

7-1. Connect the white wire from the lower switch housing to the

white wire from the fan. Connect the black/white wire from the
lower switch housing to the black wire from the fan.

Note: Both plug connectors are polarized and will only fit together

one way. Make sure the connectors are properly aligned before
connecting them. Incorrect connection could cause improper
operation and damage to the product.

7-2. Place the lower switch housing assembly over the upper switch

housing. Align the side screw holes in the upper and lower
switch housings. Attach the lower switch housing to the upper
switch housing with three housing assembly screws.

7-3. To install each shade, first loosen the three thumbscrews.
7-4. Raise the shade to the light fixture. Tighten the thumbscrews

securely.

7-5. Install B10 candelabra-based light bulbs (60 Watt maximum

each).

Note: Glass shade style and number of lights may vary.

Steps 7-4 – 7-5

Thumbscrews

Shade

Bulb

7 • Completing Your Installation With a Multi-Staked Light Fixture

Note: In compliance with US federal energy regulations, this

ceiling fan contains a device that restricts the light kit to a
maximum of 190 Watts. Exceeding that limit or the marked
limit on this product may result in fire hazard or improper
operation.

Lower

Switch

Housing

Upper

Switch

Housing

Connectors

Housing

Assembly Screw

Steps 7-1 – 7-2