CEMB USA TR-NC8 ATEX User Manual

Tr-nc/8, Cemb s.p.a, No contact transmitter

Advertising
background image

1

CEMB S.p.A.

- 23826 MANDELLO DEL LARIO (LC) I - Via Risorgimento 9

Tel. (+39)0341/706.111 - Telefax (+39)0341/706.299

www.cemb.com

e-mail: [email protected]

No contact transmitter

TR-NC/8

Certified to Directive ATEX 94/9/CE

FUNCTION

The TR-NC/8 transmitter makes the following measurements:

-

VB: Vibration (relative) of a rotor respect to its support

-

AX: Displacement (axial) of a surface with respect to a fixed point, differential

displacement between two points.

-

PH: Phase reference

The measurement is made by the correct positioning of a no contact sensor in the
vicinity of the point to be measured (made of ferrous material); the transmitter
supplies an output signal suitable for an acquisition system based on the two-wire
technique (current loop 4 to 20 mA).

The transmitter is certified for applications in areas classified as:

- Ex II 1 G Ex ia IIC T5
- Ex II 1 G Ex ia IIC T6

Advertising