RF Device Data

Freescale Semiconductor

MRFE6VP61K25HR6 MRFE6VP61K25HSR6

Table 3. ESD Protection Characteristics

Test Methodology

Class

Human Body Model (per JESD22--A114)

2 (Minimum)

Machine Model (per EIA/JESD22--A115)

B (Minimum)

Charge Device Model (per JESD22--C101)

IV (Minimum)

Table 4. Electrical Characteristics

(T

A

= 25°C unless otherwise noted)

Characteristic

Symbol

Min

Typ

Max

Unit

Off Characteristics

(1)

Gate--Source Leakage Current

(V

GS

= 5 Vdc, V

DS

= 0 Vdc)

I

GSS

1

μAdc

Drain--Source Breakdown Voltage

(V

GS

= 0 Vdc, I

D

= 100 mA)

V

(BR)DSS

125

Vdc

Zero Gate Voltage Drain Leakage Current

(V

DS

= 50 Vdc, V

GS

= 0 Vdc)

I

DSS

10

μAdc

Zero Gate Voltage Drain Leakage Current

(V

DS

= 100 Vdc, V

GS

= 0 Vdc)

I

DSS

20

μAdc

On Characteristics

Gate Threshold Voltage

(1)

(V

DS

= 10 Vdc, I

D

= 1776 μAdc)

V

GS(th)

1.7

2.2

2.7

Vdc

Gate Quiescent Voltage

(V

DD

= 50 Vdc, I

D

= 100 mAdc, Measured in Functional Test)

V

GS(Q)

1.4

2.2

2.9

Vdc

Drain--Source On--Voltage

(1)

(V

GS

= 10 Vdc, I

D

= 2 Adc)

V

DS(on)

0.15

Vdc

Dynamic Characteristics

(1)

Reverse Transfer Capacitance

(V

DS

= 50 Vdc ± 30 mV(rms)ac @ 1 MHz, V

GS

= 0 Vdc)

C

rss

2.8

pF

Output Capacitance

(V

DS

= 50 Vdc ± 30 mV(rms)ac @ 1 MHz, V

GS

= 0 Vdc)

C

oss

185

pF

Input Capacitance

(V

DS

= 50 Vdc, V

GS

= 0 Vdc ± 30 mV(rms)ac @ 1 MHz)

C

iss

562

pF

Functional Tests (In Freescale Test Fixture, 50 ohm system) V

DD

= 50 Vdc, I

DQ

= 100 mA, P

out

= 1250 W Peak (250 W Avg.), f = 230 MHz,

Pulsed, 100 μsec Pulse Width, 20% Duty Cycle

Power Gain

G

ps

23.0

24.0

26.0

dB

Drain Efficiency

η

D

72.5

74.0

%

Input Return Loss

IRL

--14

--10

dB

Pulsed RF Performance (In Freescale Application Test Fixture, 50 ohm system) V

DD

= 50 Vdc, I

DQ

= 100 mA, P

out

= 1250 W Peak

(250 W Avg.), f = 230 MHz, Pulsed, 100 μsec Pulse Width, 20% Duty Cycle

Load Mismatch

(VSWR 65:1 at all Phase Angles)

Ψ

No Degradation in Output Power

1. Each side of device measured separately.