Com-Power LI-400 User Manual

Features, Typical connection diagrams, Description

Advertising
background image

Line Impedance Stabilization Network

LI-400

Features

Frequency range of 10 kHz to 10 MHz

Fully compliant with MIL-STD 461

“Air-core” inductors to prevent saturation

Individual Calibration Included

Three-Year Warranty

The LI-400 Line Impedance Stabilization Network

(LISN) provides the necessary measurement

platform for performing power line conducted

emissions compliance testing as required by most

worldwide standards for commercial products.

The LI-400 is compliant with MIL-STD 461.

The LISN provides defined stable impedance and

isolates the EUT from power source influences,

thereby providing accurate and repeatable results.

The LI-400 includes one pair of, separately housed,

single-conductor networks, to be installed in series

with each current-carrying conductor in a single-

phase, dual-phase or DC power system. A second

LI-400 pair can be used to accommodate 3-phase

power systems (Wye or Delta configurations).

The LI-400 is equipped with Superior Electric

SUPERCON® shrouded sockets at the mains

(power input) and EUT (power output) ports. The

matching color-coded plugs for connection to the

mains and EUT wiring are included.

This LISN uses air-core inductors to prevent

saturation and permeability variation. The

mounting plate of the LI-400 is left unpainted in

order to facilitate connection to earth ground in its

installation, which is essential due to high leakage

current.

Use of a Transient Limiter for impedance matching,

reduction of out-of-band emissions and transient

protection for your measurement instrument is

highly recommended and available from Com-

Power.

All Com-Power LISNs are individually calibrated

in compliance with the relevant requirements of

MIL-STD 461. Impedance and Insertion Loss data is

supplied with each unit, along with the calibration

certificate.

Com-Power Corporation

19121 El Toro Rd., Silverado, California 92676

(949) 459 - 9600

www.com-power.com

Typical Connection Diagrams

Single Phase connection with one set of LISN

Three Phase connection with two sets of LISNs

LINE

NEUTRAL

LINE

NEUTRAL

EQUIPMENT

UNDER

TEST

POWER

SOURCE

EARTH GROUND

LISN

LISN

GROUND

GROUND

GROUND

GROUND

LINE 3

NEUTRAL

LINE 3

NEUTRAL

EQUIPMENT

UNDER

TEST

POWER

SOURCE

EARTH GROUND

LISN

LISN

GROUND

GROUND

GROUND

GROUND

LINE 1

LINE 2

LINE 1

LINE 2

LISN

LISN

GROUND

GROUND

GROUND

GROUND

Description

Rev. D04.14

Advertising