Setting Device Number and Parameters

In the next step, you’ll need to set up the device number and operation parameters for the ICC1-232. Turn the

enclosure so that the DIP switches are on the bottom as shown.

1. Make sure S2 Switch 6 is OFF (unit in Device mode).

2.

Set the Device number by turning on the switches that add up to the desired device number. For

example, for Device #259, turn on S1 switches 1 and 2 (3), S2 switch 1 (256)

Zone Switch Settings

To define the controller’s Zone #, use the following pattern of switches ON for the S2 DIP.

Zone

Value

1

2

3

4

256

512

1024 2048

1

256

X

2

512

X

3

768

X

X

4

1024

X

5

1280

X

X

6

1536

X

X

7

1792

X

X

X

8

2048

X

9

2304

X

X

10

2560

X

X

11

2816

X

X

X

12

3072

X

X

13

3328

X

X

X

14

3584

X

X

X

15

3840

X

X

X

X