Ic-net commands – Contemporary Research ICC2-ATSC+ Manual User Manual

Page 21

Advertising
background image

Contemporary Research 21

ICC2-ATSC

IC-Net Commands

Command

Description

Control

Power Off

P0

“$A5,<dh>,<dl>,2,’P0’ ” (6 bytes)

Power On

P1

“$A5,<dh>,<dl>,2,’P1’ ” (6 bytes)

Power Toggle

PT

“$A5,<dh>,<dl>,2,’PT’ ” (6 bytes)

Volume

VL

“$A5,<dh>,<dl>,3,’VL’,<vol level>” (7 bytes)
Sets TV volume level
0 = Mute

1 – 63 = Minimum level (1) to maximum volume (63)

RS-232 Control T0

“$A5,<dh>,<dl>,3,’T0’<type> ” (7 bytes) – Sets RS-232 control codes
V 2.0 – Code is fixed by firmware

IR Remote

Q8= “$A5,<dh>,<dl>,3, ‘Q8’,<IR Remote>” (7 bytes)

0=IC-RC
1=HD2-RC

Control Lock

LM

“$A5,<dh>,<dl>,3,'LM',<control>” (7 bytes)

Locks out front panel and IR remote control functions.

Bit 7

Selects IR remote control operation (0=enabled, 1=disabled)

Bit 6

Selects volume control operation (0=enabled, 1=disabled)

Bit 5 - 1 Always 0
Bit 0

Selects front panel buttons operation (0=enabled, 1=disabled)

Operating
Parameters

TM

“$A5,<dh>,<dl>,3,’TM’,<setting>” (7 bytes)
Sets up key functions in the unit

Bit 0 – Alpha channel labels
0=alpha labels off
1=alpha labels on
Bit 1 – Numeric channel labels,
0=num labels off
1=num labels on
Bit 2 – Channel up/down operation,
0=Tune Ring,
1=Send IR Keypad response
Bit 3-7 = 0

Control String

UX

"$A5,<dh>,<dl>,2+string length>,'UX'<string>" (variable bytes)
Sends an RS-232 string (ASCII, decimal, or hex) directly to the TV display.

Ex: "$A5,1,2,6,'UX, 'PON', 13" Sends PON, followed by carriage return (device 258)