D-series, Application, Available chemical-resistant materials – Delta Controls D-Series TDSSCh User Manual

Page 2: Special versions, Measuring ranges

Advertising
background image

www.delta-controls.com

D-Series

Models: S-Ch

Application

The diaphragm seal is a pressure transmitting, diaphragm-type device. The pressure signal is sent to the cooperating
pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the
separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure
measuring device from damaging impacts caused by either medium or installation:

s

High corrosiveness

s

Low or high temperature, increased viscosity, and impurities

s

Vibrations of the installation (remote diaphragm seal)

The material of both diaphragms and contact faces for the chemical-resistant diaphragm seals is corrosion resistant,
irrespective of the medium’s chemical composition and its expected concentration and temperature range.

Recommended minimum measuring range (bar)

depending on the type of the set: pressure measuring device - diaphragm seal

Diaphragm seal version

Pressure

measuring device

Diaphragm

seal type

DN50 PN16

DN80 PN40

direct

0.4

0.1

Transmitter

remote

1

0.4

Available chemical-resistant materials

Diaphragm material

Contact face material

Over pressure limit

Monel

Monel

40 bar

Hastelloy

Hastelloy

40 bar

Nickel

Nickel

40 bar

Tantalum

Tantalum

16 bar

Tantalum

Teflon

16 bar

Titanium

Titanium

40 bar

Diaphragm seals with Teflon contact faces are more economical than tantalum seals

Additional absolute zero error resulting from ambient temperature fluctuations,
depending on the type of the set: pressure transmitter - diaphragm seal

Absolute zero error per 10°C for the diaphragm seal

Diaphragm seal type

DN50

DN80

direct

5 mbar

2 mbar

remote (2 m capillary)

10 mbar

4 mbar

An additional zero error, resulting from temperature fluctuations in a medium, depends on the temperature gradient in the oil

-

based diaphragm sealing system. The error value is, in any case, significantly smaller than the error value shown in the table

Medium temperature range

-30...180°C for remote diaphragm seal

special versions up to 250°C

-30...150°C for diaphragm seal

Special versions

- Filling liquid –

FLUOROLUBE

- Direct diaphragm seal for a medium temp. over
150°C
- Gold plated wetted parts material- after consulting
with Aplisens.

Important:
- contact face in diaphragram seal DN50 have a milled slot for a gasket (acc. to DIN 2512 FormN). Version without any
slot available on request. (acc. to DIN 2526 FormE)
- standard outlet capillary from flange:
direct mounted diaphragm seal - axial
remote mounted diaphragm seal - radial

Measuring Ranges

Advertising