Advanced parameters and commands

Pearleye Technical Manual V2.3.0

47

Usage of the parameters is described in more detail on the following pages.

2

Deactivated

Test mode: Correction data

A are output as image data. (*)

3

Deactivated

Test mode: Correction data

B are output as image data. (*)

4

One-point correction: Simple subtraction of the correction data
A
from the input data. In addition the set value J is added as
offset to each pixel value.

5

One point correction: Simple subtraction of the correction data

B from the input data. In addition the set value K is added as
offset to each pixel value.

Note

(*) Operating modes 2 and 3 are for test purposes.

If you activate mode 2 or 3, the module does not transmit any
incoming image data. The module outputs correction data as
image data only.

Value

Description

Table 18: Parameter