Model hs35, Drawworks optical encoder, Figure 1 – BEI Sensors HS35 Incremental Drawworks Encoder User Manual

Page 2: Hs35 drawworks dimensions table 1, All from one source

Advertising
background image

Tel:805-968-0782

-2727 |

Fax: 805-968-3154 / 800-960-2726

7230 Holli

e., Goleta, CA 93117 |

www.beisensors.com

/ 800-350
ster Av

Specification No. 02093-001 Rev. 06/11

 

Model HS35

BEI Sensors

 

PIN ABZ ABZC

A

CH A

CH A

B

CH B

CH B

C

INDEX, Z

INDEX, Z

D

+V SUPPLY VOLTAGE

E —

F

0V/ (CIRCUIT COMMON)

G CASE

GROUND

H N/C

I N/C CH

B

J N/C CH

Z

SUPPLY

VOLTAGE TO

BARRIER

OUTPUT TYPE

FROM

BARRIER

BARRIER

PART

NUMBER

12-24 VDC Vout = 5 VDC 924-60004-002

12-24 VDC

Vout = Vin 924-60004-003

12-24 VDC

Vout = Open

Collector

924-60004-004

Part #

Cable Length

924-31186-1810 10

feet

924-31186-1820 20

feet

924-31186-1830 30

feet

924-31186-1850 50

feet

1 CYCLE

90 Deg.

HI

LO

Z

B

A

Z

B

A

CCW Rotation Viewing Face

Figure 1

Output Waveforms 

DrawWorks Optical Encoder

HS35 DrawWorks Dimensions 

Table 1

Output Terminations 

All the Components You Need

for a Complete Solution for Any
Hazardous Environment—

Table A

Disc Resolutions

(cycles per turn)

32, 100, 250, 360, 500, 512, 600, 1000, 1024,
1200, 1650, 1800, 2000, 2048, 2100, 2500,
2881, 2884, 3600, 3710, 4096, 5000

All from One Source

You no longer need to search through a
stack of catalogs, mixing and matching

sensors and barriers. With BEI’s ATEX-

approved components you can put

together a full system—encoder, cable
and barrier—with complete confidence

that all components will work together

perfectly. Integrating all three differential

data inputs, as well as power and ground
into a single, galvanically isolated barrier

reduces both engineering and installation

time. What’s more, this complete system

is Intrinsically Safe rated for ALL Gas and
Dust groups. Let us provide you with one

complete system that’s easy to specify,

easy to install, and can be used

anywhere.

A

TOLERANCES: .XX = ±0.01, .XXX = ±0.005

MS Connector Termination

BEI Intrinsic Safety Barrier

M18 Cable Assembly:

These commodities, technology or software if exported from the United States must be in accordance with the
Bureau of Industry, and Security, Export Administration regulations. Diversion contrary to U.S law is prohibited.

Advertising