Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

F

Use the buttons to set the

Gain Number to 00 and
then press ENTER.


Record the sensor reading

as a Label Value for Gain
Number 00 in a table (32
rows by four columns,

with headings similar to
those shown below.)

TRAN SENSOR GAIN


yyy (0 - 31)

00

This is the Label Value for

a gain setting of 00,
where “yyy” represents

the current sensor
reading.


Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252

01

02

…

31



Step

Action

Displayed Message

Comment

G

Use the buttons to
increment the Gain

Number by one and then
press ENTER. Record the
Label Value. Repeat this

process for each Gain
Number.

TRAN SENSOR GAIN

yyy (0 - 31)
01

These are Label Values,
where “yyy” represents

the current sensor
reading.


Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252

01 250

02 248

… …

31 09